Page 5

Downflow Furnace Filters
Downflow/Horizontal furnaces use 2 standard size perma-
nent type air filters which may be located remote to the
furnace or in the return air duct. Check with your dealer
for the location of your filters.

A downflow/horizontal furnace vertical return air filter
application, as shown, features two 14" x 20" x 1" filter in
the 14-1/2" wide furnace cabinets; or two 16" x 20" x 1" filter
in the 17-1/2", 21", and 24-1/2" wide furnace cabinets.

A downflow/horizontal furnace with horizontal return air
filter application, as shown, features two 14" x 20" x 1"
filter in the 14-1/2" wide furnace cabinets; or two 16" x 20"
x 1" filter in the 17-1/2", 21", and 24-1/2" wide furnace
cabinets.

DOWNFLOW FILTER TABLE

REQUIRED FILTERS - DOWNFLOW

CABINET WIDTH

FILTER QUANTITY & SIZE

14-1/2"

2 - 14" X 20" X 1"

17-1/2"

2 - 16" X 20" X 1"

21"

2 - 16" X 20" X 1"

24-1/2"

2 - 16" X 20" X 1"

FACTORY SUPPLIED UPFLOW FURNACE

RETURN AIR FILTERS

UPFLOW FURNACE RETURN AIR FILTERS

CABINET

WIDTH

QTY*

CABINET

BOTTOM FILTER

CABINET

SIDE FILTER

14-1/2"

1

14" X 25" X 1"

17-1/2" X 25" X 1"

17-1/2"

1

17" X 25" X 1"

17-1/2" X 25" X 1"

21"

1

20" X 25" X 1"

17-1/2" X 25" X 1"

24-1/2"

1

24" X 25" X 1"

17-1/2" X 25" X 1"

*NOTE - On 5 or 6 ton airflow models, if the airflow

requirement exceeds 1800 CFM, these models will require

filters on

both sides; OR 1 side and the bottom; OR just the

bottom.

DOWNFLOW FILTER

DOWNFLOW/HORIZONTAL FILTER

WARNING:

Disconnect power to the

unit before removing the blower door. Failure to
follow this warning could result in property damage,
personal injury or death.