Exhaust system – Alliance Laundry Systems SFGX09*F User Manual

Page 15

Advertising
background image

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

Installation

13

510977

Exhaust System

For best drying results, recommended maximum
length of exhaust system is shown in Table 1.

To prevent backdraft when dryer is not in operation,
outer end of exhaust pipe must have a weather hood
with hinged dampers (obtain locally).

NOTE: Weather hood should be installed at least
12 inches (30.5 cm) above the ground. Larger
clearances may be necessary for installations where
heavy snowfall can occur.

Table 1

Number of

90° Elbows

Weather Hood Type

Recommended

Use Only for Short Run Installations

Maximum length of 4 in. (10.2 cm) diameter rigid metal duct.

0

65 feet (19.8 m)

55 feet (16.8 m)

1

55 feet (16.8 m)

47 feet (14.3 m)

2

47 feet (14.3 m)

41 feet (12.5 m)

3

36 feet (11.0 m)

30 feet (9.1 m)

4

28 feet (8.5 m)

22 feet (6.7 m)

Maximum length of 4 in. (10.2 cm) diameter flexible metal duct.

0

45 feet (13.7 m)

35 feet (10.7 m)

1

35 feet (10.7 m)

27 feet (8.2 m)

2

30 feet (9.1 m)

21 feet (6.4 m)

3

25 feet (7.6 m)

17 feet (5.2 m)

4

20 feet (6.1 m)

15 feet (4.5 m)

NOTE: Deduct 6 feet (1.8 m) for each additional elbow.

4 in.

(10.2 cm)

4 in.

(10.2 cm)

D673I

D802I

2-1/2 in.

(6.35 cm)

Advertising
This manual is related to the following products: