Ctp series, External seal probe connections – HOMA CTP Series User Manual

Page 9

Advertising
background image

CTP Series

Installation, Operation & Maintenance Manual

SEAL PROBE INSTALLATION PROCEDURE


Mechanical Seal Leak Detection probe has been loose to protect from shipping

damage. Please follow this procedure to install the probe.

1)

Lay pump on its side with the plug on the seal chamber facing upwards as indicated.

2)

Unscrew the plug with the proper wrench, taking care not to damage the sealing surface.

3)

Verify that seal chamber oil level is within ¼” of the indicated value. Measurement is from oil level
to the top of hole. See IOM Manual for seal chamber oil volume, if required.

4)

Remove the new sealing gasket from package and install it onto the seal probe plug.

5)

Install the seal probe with gasket into the opening, taking care not to damage the cable. Then
tighten the seal probe with the proper wrench until snug. Do not overtighten. Once

tight, verify the

seal gasket is properly seated and the cable is not pinched or twisted. NOTE: At installation of the
seal probe be careful not to bind the seal probe cord as it is being installed into the pump.

6)

Lift pump into a vertical position and inspect for any leaks.

7)

Secure seal probe cable to pump body and power cable with tyraps before installing pump.

External Seal Probe Connections

Pg.

Advertising