H series – HOMA H Series User Manual

Page 8

Advertising
background image

H Series

P U M P

Installation, Operation, and Maintenance Manual



PREVENTIVE MAINTENANCE


Regular preventive maintenance will help ensure
longer pump life and more reliable operation. It
is recommended that pumps in intermittent
operation be inspected twice a year and pumps
in continuous operation be inspected every
1,000 hours. The following is a listing of required
inspection and maintenance items. (Refer to
shop manual for disassembly and reassembly
procedures).

If any of the problems described in the
following list exists stop operating the pump
to avoid damage or personal injury.

1. CABLE ENTRY

Make sure that the cable entry flange and strain
relief clamp are tight. If the cable entry is
showing signs of leakage remove cable from
entry, remove grommet, cut a piece of cable off
so that the grommet seats on a new portion of
the cable, replace grommet, and reinstall cable
assembly, into the top of the motor.

2. CABLES

Inspect the cable for cuts, scrapes or sharp
bends. If the outer jacket is damaged, replace
the cable. Do not attempt splices within wetwells

3. MOTOR INSULATION RESISTANCE

Megger the insulation between the phases and
between any phase and ground. Resistance
values should be greater than 1 M ohm. If
abnormal readings are obtained contact
authorized service center immediately.

4. EXTERNAL PARTS ON PUMP

Make sure that all screws, bolts and nuts are
tight. Check the condition of pump lifting eyes
and replace if damaged or worn, Replace any
external part that appears worn or damaged.


5. SEAL CHAMBER OIL

Check the condition of the oil to see if any water
leakage has occurred. Remove the oil fill plug.
Drain the oil from the seal chamber into a
transparent container. Check for impurities and
emulsification. (Oil is cream-like.) If water
intrusion has occurred check lower mechanical
seal and replace if necessary. Refill seal
chamber with fresh oil. Refer to shop manual for
type and quantity of oil.


6. IMPELLER

Periodically inspect impeller by turning
pump on its side, remove suction strainer
nuts and strainer to expose impeller and
relocate position of adjusting plate
(suction cover) as needed. Replace the
impeller if it is damaged or severely
worn.

SPARE PARTS

In order to obtain spare parts identify the
required parts by looking at the enclosed cross
sectional drawing and listing, and contact
authorized HOMA PUMP TECHNOLOGY
representative with your order. Authentic Homa
Pump Technology parts shall be used to
maintain warranty.


RECOMMENDED TOOLS AND
SUPPLIES

In addition to ordinary, standard tools, ensure
that complete set of metric socket wrenches,
complete set of Allen wrenches, metric triangular
wrench set, dead blow hammer, impeller puller,
Loctite 242 (Blue), petroleum jelly and anti- seize
compound are on hand.

If you need additional help,

please call us at:

1 (800) 452 - HOMA