Hudson Valley Lighting EDISON COLLECTION 719 User Manual

Hudson Valley Lighting Lighting

Advertising
background image

587 & 719
















Electrical tape

Approved fastener
(Wire nut)













Hudson Valley Lighting, Inc.
P.O. Box 7459
106 Pierces Road
Newburgh, NY 12550
(800) 814-3993

www.hudsonvalleylighting.com

GENERAL
1. To ensure the success of the fixture installation, the following instructions and
diagram(s) should be read and understood.
2. All electrical connections must be made in accordance with the National Electric
code and local codes and ordinances. If you are uncertain of the methods of
installing electrical wiring and lighting fixtures secure the services of a qualified
licensed electrician.
3. TOOLS NEEDED: Blade screwdriver, phillips screwdriver, slip joint pliers or
small adjustable wrench, wire cutter/stripper, electrical current tester, stepladder
and electrical tape. NOTE: The important safeguards and instructions outlined on
this sheet are not meant to cover all possible conditions and situations that may
occur. It must be understood that common sense, caution and care are factors that
cannot be built into any product. Caution and care must be supplied by the
person(s) installing, operating and maintaining this lighting fixture.
INSTALLATION PREPARATION

1. TURN OFF THE ENTIRE ELECTRICAL CIRCUIT TO WHICH THE LIGHTING
FIXTURE IS TO BE ATTACHED.

Move the appropriate circuit breaker to the “off

position or completely remove the fuse controlling the circuit.
2. If an existing fixture is being replaced, remove it and note to which of the wires
in the outlet box the fixture was attached.

DO NOT SEPARATE ANY OTHER

WIRES THAT MAY BE IN THE BOX. DO NOT DAMAGE THE INSULATION OF
OLDER WIRING.

In regular circumstances the BLACK wire will be the “Hot” lead

and the WHITE wire will be the “Neutral” or “Common” lead. A GREEN or BARE

COPPER wire is the “Ground”. In older buildings it is always good practice to
reconfirm the polarity of the wiring.
3. This fixture is designed to be mounted on a standard round or octagon box. The
box must be securely mounted to the structure of the building.
FIXTURE INSTALLATION
1. Attach the crossbar to the outlet box. (The green screw should face the floor)
2.Thread the nipple into the crossbar and the hex nut onto the nipple. Adjust the

nipple so that it extends 3/16” beyond the surface of the fixture. Lock the hex nut

against the crossbar.
3. Fasten the green fixture wire to the green or bare copper wire in the box or
fasten it to the mounting plate with green screw provided.

NEVER FASTEN THE GROUND WIRE TO THE BLACK OR “HOT” WIRE!
FAILURE TO FOLLOW THIS INSTRUCTION COULD RESULT IN SERIOUS
INJURY OR DEATH!

4. Fasten the white fixture wire to the white wire in the outlet box. Fasten the wires
to together with an approved fastener (wire nut).
Starting about 1” below the fastener, tightly wrap connection with electrical tape so
that the tape seals the end of the fastener.
Make sure that there is no exposed wire or strands that could cause a dangerous
short circuit !
5. Connect the black fixture wires to the black wire in the outlet box.
Fasten the joined wires as in step 4.
6. Using the finial, loosely fasten the fixture to the outlet box. Adjust the orientation
of the fixture and tighten the finial.
7.Install the glass. The thumb screws should be FINGER TIGHT ONLY!
8. Install the lamp(s) light bulb(s).
NOTE: This fixture is rated for 60 watt type A lamp(s).

DO NOT EXCEED RECOMMENDED WATTAGE !

9. Restore power to circuit at breaker or fuse box.

Outlet box

Crossbar

Green screw

Hex nut

Nipple

Thumb screw

Cap nut

Glass

Advertising
This manual is related to the following products: