Hudson Valley Lighting JEFFERSON 5219 User Manual

Hudson Valley Lighting Lighting

Advertising
background image

5216 & 5219




Hudson Valley Lighting, Inc.

P.O. Box 7459

106 Pierces Road

Newburgh, NY 12550

(800) 814-3993

www.hudsonvalleylighting.com

GENERAL
1. To ensure the success of the fixture installation, the following

instructions and diagram(s) should be read and understood.

2. All electrical connections must be made in accordance with the

National Electric code and local codes and ordinances. If you are

uncertain of the methods of installing electrical wiring and lighting

fixtures secure the services of a qualified licensed electrician.

3. TOOLS NEEDED: Blade screwdriver, phillips screwdriver,

slip joint pliers or small adjustable wrench, wire cutter/stripper,

electrical current tester, stepladder and electrical tape. NOTE: The

important safeguards and instructions outlined on this sheet are

not meant to cover all possible conditions and situations that may

occur. It must be understood that common sense, caution and care

are factors that cannot be built into any product. Caution and care

must be supplied by the person(s) installing, operating and

maintaining this lighting fixture.


INSTALLATION PREPARATION

1. TURN OFF THE ENTIRE ELECTRICAL CIRCUIT TO WHICH

THE LIGHTING FIXTURE IS TO BE ATTACHED.

Move the

appropriate circuit breaker to the “off position or completely remove

the fuse controlling the circuit.

2. If an existing fixture is being replaced, remove it and note to

which of the wires in the outlet box the fixture was attached.

DO

NOT SEPARATE ANY OTHER WIRES THAT MAY BE IN THE

BOX. DO NOT DAMAGE THE INSULATION OF OLDER WIRING.

In regular

circumstances the BLACK wire will be the “Hot” lead and the

WHITE wire will be the “Neutral” or “Common” lead. A GREEN or

BARE COPPER wire is the “Ground”. In older buildings it is always

good practice to reconfirm the polarity of the wiring.

3. This fixture is designed to be mounted on a standard round or

octagon box. The box must be securely mounted to the structure

of the building.

FIXTURE PREPARATION
1. Remove the fixture, shades and parts bag(s) from the carton.

Before discarding the carton, double check packing to make

certain that all parts are found.

2. Assemble the stem, scroll and loop assembly to the fixture body.

FIXTURE INSTALLATION

1. Attach the crossbar to the outlet box. (The green screw should

face the floor)

2. Remove the threaded ring from the screwcollar loop. Fully

thread the loop onto the nipple. Thread the hex nut onto the

nipple and the nipple into the crossbar. Place the canopy over the

screwcollar loop and against the ceiling. Adjust the nipple so that

¼” of threads on the screwcollar loop extend beyond the canopy.

Tighten the hex nut against the crossbar.

3. Open end links of chain to the screwcollar loop. Close the top

link of chain. Hang the fixture on the chain at the desired height.

Remove the excess chain. Close the bottom link of chain.

Outlet box

Green screw

Crossbar

Nipple

Canopy

Screwcollar loop

ring

Chain

Approved fastener

(Wire nut)

Electrical tape

Advertising