GENERAL
1.
To insure the success of the fixture installation, the following instructions and diagram(s)
should be read and understood.
2. All electrical connections must be made in accordance with the National Electric code and
local codes and ordinances. If you are uncertain of the methods of installing electrical wiring
and lighting fixtures secure the services of a qualified licensed electrician.
3. TOOLS NEEDED: Blade screwdriver, slip joint pliers, wire cutter/stripper, electrical current
tester, stepladder and electrical tape. NOTE: The important safeguards and instructions
outlined on this sheet are not meant to cover all possible conditions and situations that may
occur. It must be understood that common sense, caution and care are factors that cannot be
built into any product.
Caution and care must be supplied by the person(s) installing, operating and maintaining this
lighting fixture.
INSTALLATION PREPARATION
1. TURN OFF THE ENTIRE ELECTRICAL CIRCUIT TO WHICH THE LIGHTING FIXTURE IS
TO BE ATTACHED.
Move the appropriate circuit breaker to the “off position or completely
remove the fuse controlling the circuit.
2. If an existing fixture is being replaced, remove it and note to which of the wires in the outlet
box the fixture was attached.

DO NOT SEPARATE ANY OTHER WIRES THAT MAY BE IN

THE BOX. DO NOT DAMAGE THE INSULATION OF OLDER WIRING.

In regular circumstances the BLACK wire will be the “Hot” lead and the WHITE wire will be the
“Neutral” or “Common” lead. A GREEN or BARE COPPER wire is the “Ground”. In older
buildings it is always good practice to reconfirm the polarity of the wiring.
3. This fixture is designed to be mounted on a standard round or octagon box. The box must be
securely mounted to the structure of the building.
FIXTURE INSTALLATION
1.
Remove the fixture and parts bag(s) from the carton. Before discarding the carton, double
check packing to make certain that all parts are found.
2. Remove the 4 screws holding the mounting plate to the fixture.
3. Pull the wires in the outlet box through the center hole of the mounting plate. Attach the
mounting plate to the outlet box. (The green ground screw should face out). Adjust the plate so
that it is level.
4. Fasten the bare copper fixture wire to the green or bare copper wire in the box
or fasten the green or bare copper wire in the box to the mounting plate with green screw
provided.

NEVER FASTEN THE GROUND WIRE TO THE BLACK OR “HOT” WIRE ! FAILURE TO
FOLLOW THIS INSTRUCTION COULD RESULT IN SERIOUS INJURY OR DEATH !

5. Fasten the white fixture wire to the white wire in the outlet box. Fasten the wires to together
with an approved fastener (wire nut). Starting about 1” below the fastener, tightly wrap
connection with electrical tape so that the tape seals the end of the fastener.
Make sure that there is no exposed wire or strands that could cause a dangerous short
circuit !
6.
Connect the black fixture wires to the black wire in the outlet box. Fasten the joined wires as
in step 5.
7. Place the fixture over the mounting plate and fasten it in place with the 4 screws.
8. Remove the ring(s) from the threaded socket(s). Install the shade and replace the ring(s).
9. Install the lamp(s) (light bulb(s).
NOTE: This fixture is rated for 60 watt type B, BA, C or CA lamp(s).
DO NOT EXCEED RECOMMENDED WATTAGE !
10.
Restore power to circuit at breaker or fuse box.

Approved fastener
(Wire nut)

Electrical tape