Specifications – Hydra-Flex Aqua-Lab SD Installation Manual User Manual

Page 2

Advertising
background image

Installation Manual

© Hydra-Flex Inc 2011

Specifications

1.

Operating water pressure: 200 psi (Factory set)

2.

Pneumatics operating pressure: 60-80 psi (for air valve systems)

3.

Maximum water source temperature 140° F

4.

Operating ambient temperature: 40-120° F

5.

Electrical supply(if pump system purchased from HFI)

a. 120 single phase or 208/230 (3-phase)
b. 1.5 hp pump 18 amps @ 120 volts single phase or 9 amps @ 230 volts single phase
c. 1.5 hp pump 9 amps @ 230 volts three phase or 4.5 amps @ three phase

6.

Operate solenoid valves with 24VAC, 24VDC, 120VAC

a. 1.5 amp per port electric solenoids
b. .3 amp per port air solenoids

7.

Water supply

a. 3/4” ID Line single operating pump feed
b. Inlet pressure: 2-80 psi

i. If pumps are fed from tank, water level must be 54” above pumps.

8. Air supply

a. 3/8” feed
b. 1 CFM @ 70 psi supply

9. Solution lines

a. ½” poly lines (3/4” for high flow applications such as rain bars)

10. Space requirements:

a. AQUA-LAB Systems

i. SD model – 2’ wide x 1.5’ high of wall space

b. Pump assemblies – pumps need to be within 6’ of the system to allow connection with the connection

hose included (longer connections can be run with customer supplied hose)

i. Single pump wall mount – 4’ x 1’ wall space

c. Electrical enclosures

i. Motor starter – 1.5’ wide x 1.5’ high of wall space






For Additional Support Call:

952.808.3640