Troubleshooting - Control Valve

Problem

Cause

Correction

1. Water conditioner fails to

regenerate.

A. Electrical service to unit has

been interrupted

A. Assure permanent electrical service

(check fuse, plug, pull chain, or switch)

B. Timer is defective.

B. Replace timer.

C. Power failure.

C. Reset time of day.

2. Hard water.

A. By-pass valve is open.

A. Close by-pass valve.

B. No salt is in brine tank.

B. Add salt to brine tank and maintain

salt level above water level.

C. Injector screen plugged.

C. Clean injector screen.

D. Insufficient water flowing into

brine tank.

D. Check brine tank fill time and clean

brine line flow control if plugged.

E. Hot water tank hardness.

E. Repeated flushings of the hot water

tank is required.

F. Leak at distributor tube.

F. Make sure distributor tube is not

cracked. Check O-ring and tube pilot.

G. Internal valve leak.

G. Replace seals and spacers and/or

piston.

3. Unit used too much salt.

A. Improper salt setting.

A. Check salt usage and salt setting.

B. Excessive water in brine tank.

B. See problem 7.

. Loss of water pressure.

A. Iron buildup in line to water

conditioner.

A. Clean line to water conditioner.

B. Iron buildup in water

conditioner.

B. Clean control and add mineral cleaner

to mineral bed. Increase frequency of

regeneration.

C. Inlet of control plugged due

to foreign material broken loose

from pipes by recent work done on

plumbing system.

C. Remove piston and clean control.

5. Loss of mineral through drain

line.

A. Air in water system.

A. Assure that well system has proper

air eliminator control. Check for dry well

condition.

B. Improperly sized drain line flow

control.

B. Check for proper drain rate.

6. Iron in conditioned water.

A. Fouled mineral bed.

A. Check backwash, brine draw, and

brine tank fill. Increase frequency of

regeneration. Increase backwash time.

7. Excessive water in brine

tank.

A. Plugged drain line flow control.

A. Clean flow control.

B. Plugged injector system.

B. Clean injector and screen.

C. Timer not cycling.

C. Replace timer.

D. Foreign material in brine valve.

D. Replace brine valve seat and clean

valve.

E. Foreign material in brine line

flow control.

E. Clean brine line flow control.