Operating instructions – Hydrotech ProFlo SXT Valve Downflow_Upflow Automatic Water Softeners Operation Manual User Manual

Page 8

Advertising
background image

Operating Instructions

Figure 4A - UPFLOW

The valve has been pre-programmed with factory settings as follows:

Regeneration Cycle Step Programming - Upflow
1. Brine Rinse ........60 minutes
2. Backwash .........10 minutes
3. Rapid Rinse ......10 minutes
4. Brine Refill ........7 minutes - 0.75 cu. ft.

8 minutes - 1.0 cu. ft.
13 minutes - 1.50 cu. ft.
9 minutes - 2.0 cu. ft.

Figure 4B - DOWNFLOW

The valve has been pre-programmed with factory settings as follows:

Regeneration Cycle Step Programming - Downflow
1. Backwash .........10 minutes
2. Brine Rinse ........60 minutes
3. Rapid Rinse ......10 minutes
4. Brine Refill ........7 minutes - 0.75 cu. ft.

8 minutes - 1.0 cu. ft.
13 minutes - 1.50 cu. ft.
9 minutes - 2.0 cu. ft.