PROBLEM

CAUSE

G) Water distiller runs
properly but little or no
water is produced.

1. Improper Heating Element is installed or Heating

Element is faulty. Call Service Center.

2. Auto drain valve is partially stuck open due to

scale build up in the valve. Check valve and/or
flush by pouring water through the top of the
boiler tank opening.

3. Auto drain valve is open because it is not

plugged into the water distiller head. Check and
re-connect.

4. Boiler tank lid is loose. Check by moving Boiler

Tank Lid Knob.

5. Reset button may be defective or weak. See A)

3 above.

6. Water supply may be restricted. Turn off saddle

valve. Remove Feed Water line from back of
water distiller. Place Feed Water line into a pail,
turn on saddle valve and check water flow.

H) Strange taste in Distilled
Water.

1. Boiling tank and/or storage tank may require

cleaning. See maintenance section on cleaning
water distiller.

2. Boiling tank has over filled, float system or water

solenoid has failed and allowed un-distilled
water to overflow into the cooling coil. Open
boiler tank and check float operation.

3. Charcoal filter requires new Coconut Charcoal.
4. Auto-Drain has malfunctioned. Check boiling

tank for scale build up. See maintenance
section.

5. Distilled water line may need cleaning. See

maintenance section.

I) Fan does not operate
automatically.


1. Fan switch is in OFF position. Check Switch.
2. Fan motor may be defective. Call Service

Center.

3. Storage tank is full and the water distiller has

shut it self off until the storage tank is only 2/3
full.

Advertising