Leak Detector Reset Instructions
Your
Max or Max Plus cooler comes with a leak detector installed in the cabinet of the cooler.
The cabinet floor comes with a built in trough to catch any water.
In the trough are two (2) probes that are wired to the leak detector.
Should the probes detect water in the trough, a signal is sent to the
leak detector and automatically shuts off the water supply to your
Max
or Max Plus cooler.
Note that the red switch has popped out from the side of the leak detector.
steps to Reset the Leak Detector
a. Unplug the power supply.
b. Shut off all switches on the back of the cooler.
c. Clean and dry all water on the floor and in the trough.
d. Reset the red trip switch by pushing up and in on the red switch.
Plug the unit into a 120V outlet. For the
Max Plus with UV system installed, verify the pump has primed as
discussed on page 2 of this manual. Turn on the Hot and Cold power switches.