Cashco P5 User Manual

Model p5

Advertising
background image

INSTALLATION, OPERATION & MAINTENANCE MANUAL (IOM)

IOM-P5

11/13

SECTION I

I. DESCRIPTION AND SCOPE

The Model P5 is a pressure reducing regulator used to control downstream (outlet or P

2

) pressure. The unit is suitable

for gaseous or liquid services. Available in sizes 1/4" (DN8), 3/8" (DN10) and 1/2" (DN15). Refer to Technical Bulletin
P5-TB for design conditions and selection recommendations.

SECTION II

II. INSTALLATION

MODEL P5

PISTON SENSING SINGLE STAGE

PRESSURE REDUCING REGULATOR

1. An inlet block valve should always be installed.

2. If service application is continuous such that

shut down is not readily accomplished, it is rec-
ommended that an inlet block valve, outlet block
valve, and a manual bypass valve be installed.

3. Pipe unions should be installed to allow removal

from piping.

4. An outlet pressure gauge should be located ap-

proxi mately ten pipe diameters downstream, and
within sight.

5. All installations should include a downstream re lief

de vice if the inlet pressure could exceed the pres-
sure rating of any downstream equip ment or the
maximum outlet pressure rating of the unit.

6. Clean the pip ing of all foreign material including

chips, welding scale, oil, grease and dirt before in-
stalling the reg u la tor. Strainers are rec om mend ed.

CAUTION

Installation of adequate overpressure pro tec tion
is recommended to pro tect the reg u la tor from
over pres sure and all down stream equip ment from
dam age in the event of regulator failure.

7. In plac

ing thread seal ant on pipe ends pri or to

en gage ment, ensure that excess material is re-
moved and not allowed to enter the regulator upon
startup.

8. Flow Direction: Install so the fl ow direction match es

the inlet stamp on the main regulator body (1).

9. For best performance, install in well drained hori-

zon tal pipe.

10. Basic Regulator - (Refer to Figure 2): Regulator

may be rotated around the pipe axis 360°. Recom-
mended position is with knob (4) ver ti cal upwards.

11. Regulators are not to be buried un der ground.

12. For insulated piping systems, recommendation is

to not insulate regulator.

Advertising