A1301, A1302 – Allegro Multimedia A1302 User Manual

Page 3

Advertising
background image

Continuous-Time Ratiometric

Linear Hall Effect Sensors

A1301

and

A1302

3

Allegro MicroSystems, Inc.

115 Northeast Cutoff, Box 15036

Worcester, Massachusetts 01615-0036 (508) 853-5000
www.allegromicro.com

DEVICE CHARACTERISTICS

over operating temperature range, T

A

, and V

CC

= 5 V, unless otherwise noted

Characteristic

Symbol

Test Conditions

Min.

Typ.

Max.

Units

Electrical Characteristics
Supply Voltage

V

CC

Running, T

J

< 165°C

4.5

6

V

Supply Current

I

CC

Output open

11

mA

Output Voltage

V

OUT(High)

I

SOURCE

= –1 mA, Sens = nominal

4.65

4.7

V

V

OUT(Low)

I

SINK

= 1 mA, Sens = nominal

0.2

0.25

V

Output Bandwidth

BW

20

kHz

Power-On Time

t

PO

V

CC(min)

to 0.95 V

OUT;

B = ±1400 G;

Slew rate = 4.5 V/μs to 4.5 V/100 ns

3

5

μs

Output Resistance

R

OUT

I

SINK

≤ 1 mA, I

SOURCE

≥ –1 mA

2

5

Ω

Wide Band Output Noise, rms

V

OUTN

External output low pass filter ≤ 10 kHz;
Sens = nominal

150

μV

Ratiometry
Quiescent Output Voltage Error
with respect to ΔV

CC

1

ΔV

OUTQ(V)

T

A

= 25°C

±3.0

%

Magnetic Sensitivity Error with
respect to ΔV

CC

2

ΔSens

(V)

T

A

= 25°C

±3.0

%

Output
Linearity

Lin

T

A

= 25°C

±2.5

%

Symmetry

Sym

T

A

= 25°C

±3.0

%

Magnetic Characteristics
Quiescent Output Voltage

V

OUTQ

B = 0 G; T

A

= 25°C

2.4

2.5

2.6

V

Quiescent Output Voltage over
Operating Temperature Range

V

OUTQ(

ΔT

A

)

B = 0 G

2.2

2.8

V

Magnetic Sensitivity

Sens

A1301; T

A

= 25°C

2.0

2.5

3.0

mV/G

A1302; T

A

= 25°C

1.0

1.3

1.6

mV/G

Magnetic Sensitivity over
Operating Temperature Range

Sens

(

ΔT

A

)

A1301

1.8

3.2

mV/G

A1302

0.85

1.75

mV/G

1

Refer to equation (4) in Ratiometric section on page 4.

2

Refer to equation (5) in Ratiometric section on page 4.

Advertising
This manual is related to the following products: