2

Figure 1: Installation Orientation

SECTION III

SECTION IV

IV. INSTALLATION

A. Orientation:

1. Standard orientation is with the yoke with

position indicator plate and valve body outlet
port in same plane. If an alternate ar range-
ment is necessary, loosen yoke nut (8)
se cur ing yoke (3) to valve bonnet (2) ap prox i-
mate ly three revolutions. Rotate actuator as-
sembly (AA) to de sired po si tion with re spect to
body as sem bly (BA). Re-tighten yoke nut (8)
to 85 ft-# (115 N M). NOTE: This pro ce dure
can be done in-line.

2. Valve body must be installed in a horizontal or

vertical plane where the outlet connection fl ow
direction is down wards or horizontal. Failure
to comply will cause the self-draining of the
internal passages to be nullifi ed, allowing CIP
clean ing/fl ushing fl uids to be ponded. See
Figure 1.

A. Clean-in-Place (CIP):

1. Control valve unit must be properly oriented

per Sec tion IV.A. to assure self-draining of
valve’s internal pas sag es.

2. Control valve unit comes in the direct action,

ATC-FO arrangement or the reverse action,
ATO-FC ar range ment. Valve should be in
the full open po si tion before initiation of the
CIP pro ce dure. Control system must ac com-
mo date this ca pa bil i ty.

3. Cleaning

fl uid may fl ow in either direction.

4. Cleaning

fl uid pressure must not exceed 50

psig (3.4 Barg).

5. Cleaning

fl uid temperature must not exceed

366°F (186°C).

6. Cleaning

fl uid must be compatible with wetted

ma te ri als.

III. OPERATION CONSIDERATIONS

B. Steam-in-Place (SIP):

1. Orientation to be same as CIP,Section III.A.1.

2. Steam

may

fl ow from either direction.

3. Recommended 30 psig @ SAT (2.1 Barg @

SAT). Valve must be in the full open during
the SIP pro ce dure.

C. Hose-Down Cleaning:

1. Standard Model SCV-S control valve units

supplied with I/P positioners are NOT de signed
to allow hose-down wash ing of the unit’s ex-
te ri or.

D. Instrument Air Supply - IAS:

1. For Model SCV-S with a positioner rec om mend

using cryogenically pro duced nitrogen gas,
or oil-free com pressed air des ic cant dried to
-40°F(-40°C) dew point, fi l tered to 10 mi crons
or less as the IAS source.

2. All exhaust/vent air utilized by the Model

SCV-S unit enters the ambient en vi ron ment.

VERTICAL DOWN

OUTLET

HORIZONTAL

OUTLET

Straight Pattern

Angle Pattern