System powering, System powering -2 – Clear-Com CS-702 User Manual

Page 18

Advertising
background image

C S - 7 0 2 T W O - C H A N N E L M A I N S T A T I O N

2 - 2

No power supply. Derives power from the intercom line.

May or may not have terminations.

D. POWER SUPPLY:

Supplies system power for external stations.

Provides switch-selectable terminations.

SYSTEM POWERING

Typical Clear-Com systems consist of a main station and multiple remote
stations. The remote stations are powered from the main station through the
intercom cable (Figure 2-5).

Figure 2-5 Typical Single Power Source System

Clear-Com power supplies can be paralleled to increase the number of remote
stations that can be operated in a system (Figure 2-6). The termination
switches in the second power source would need to be in the off position.

Note: The RMK function will not work on a system that has two or more

power supplies.

Figure 2-6 System With Multiple Power Sources