Step 3, Figure 6: rack mount panel with lid removed – Clear-Com V24PDXY User Manual

Page 5

Advertising
background image

Clear-Com Communication Systems

V-Series AES-3 Option

© Clear-Com Communication Systems

5

PN 810388Z Rev. 2

Step 3

Figure 6: Rack Mount Panel with Lid Removed

There are two cutouts and four screw holes in the rear metalwork which are
covered from the outside by the plastic overlay. The overlay covering the
cutouts and screw holes must be removed before the AES-3 card can be
inserted. This should be done using a small sharp blade such as a scalpel or
craft knife. Care must be taken to avoid any damage to the electronics or
cables in the panel while doing this.

Pressing on the overlay will highlight the position of the holes.

Note: Ensure that no pieces of overlay are left inside the panel once the
cutouts are cleared as the overlay itself is conductive and could cause
damage to the panel.

Figure 7: Rack Mount Panel with Overlay Removed from Cutouts