Specifications – Clear-Com RLY-6 User Manual

Page 13

Advertising
background image

Vitec Group Communications

RLY-6 Interface Instruction Manual

3 - 1

SPECIFICATIONS

Relay

Type

1 Form C

Quantity

6

Contact Max. Volts

24 volts DC

Contact Max. Cur.

1 ampere continuous,
(2 amperes peak at 24 volts DC
(resistive load)

DC Isolation

10 mega-ohms

Module Power Supply Requirements

Voltage Required

8 – 10 volts DC

Current Required

150 mA max (25 mA per relay
when active)

Connectors

Relay Contacts

2 ea. DB-9M

Matrix Connection

2 ea. RJ-45 each

Indicators and Controls

LED Indicators

6 Green (1 ea. per relay)

1 Yellow (Frame Data)

Pushbutton Switches

6 (1 Test Pushbutton per relay)

Wiring Requirements

Maximum line lengths for connection to Matrix Frame
Matrix Frame to interface frame shall be less than 15 feet ( 5 meters)
Maximum line length between interface frame inputs 6 inches (15 cm)

Operating Environment

Temperature

0 and 70° C (32 -150° F)

Package Dimensions

Height

5 1/16" (129 mm)

Width

1 3/8" (35 mm)

Depth

9 5/32" (233 mm)

Weight

.35 LBS (.15 kg)

Notice About Specifications

While Vitec Group Communications makes every attempt to maintain
the accuracy of the information contained in its product manuals, that
information is subject to change without notice. Performance
specifications included in this manual are design-center specifications
and are included for customer guidance and to facilitate system
installation. Actual operating performance may vary.

3

Advertising