2 - 1

INSTALLATION

To install the IFB-104:
1. Connect the female XLR-3 connectors (J101, J201, J301, and/or

J401) to the program feed(s).

2. Connect the RJ-45 connectors (J102, J202, J302, and/or J402) to a

Matrix frame.

3. Configure the Matrix port through the Eclipse Configuration Software

(ECS), which has declared the IFB-104 as a direct 4-wire port
connection.

4. Connect the XLR-3 male (J103, J203, J303, and/or J403) to an on-

air talent receiver.

5. Move the slide switch to WET if the on-air talent receiver requires

power and to DRY if it doesn’t require power. Use the WET setting
with a Clear-Com talent receiver.

6. Connect power to the appropriate connector on the left of the back

panel.

Following is an illustration of how one panel can be connected to an
on-air talent receiver that requires power using the IFB-104.

Figure 2-1: IFB-104 Connections