Eclipse Upgrade Reference Manual

Clear-Com Communication Systems

Page 29 of 155

Part Number: 810377Z Rev 6

• Path: InstallCD\Omega-Median\710621Z - Config App\710621Z.4kr

Figure 19 - Config Card Application File

22. Confirm that numbers counting up are displayed on the configuration card LED

matrix. Note: The count up display indicates that packets are being received by
the configuration card and do not represent a percentage complete.
If the download fails the CPU display will show “LD Err”. The TeraTerm screen
will not indicate a failure and will continue to download. In this case abort the
TeraTern download, RESET the CPU card (by removing and reinserting) and
restart the download.

23. Once the download is complete, the CPU card should be left with all lights lit

and the status light blinking.

24. Confirm that the configuration card resets and restarts correctly and that the

OK LED on the front of the card double flashes indicating that there is no
configuration map present in the card.

25. Remove the updated configuration card and set the DIP switches to have

watchdogs enabled (this is the normal operating mode).


Advertising