Rubberized access cover, Usb mini b connector, Pairing connector – Clear-Com CB-222 User Manual

Page 13: Belt clip, Power on/off butt on, Batt ery compartment, Headset connector

Advertising
background image

9

Tempest®24 00 MasterBelt

1- Rubberized Access Cover

The Rubberized Access Cover helps prevent dust, dirt and liquid from entering the BeltStati on

through the USB or the BeltStati on pairing connector. Keep this cover securely closed at all ti mes

to ensure the best possible seal.

2- USB Mini B Connector

The USB Connector is used to charge the BeltStati on with the supplied wall charger. In additi on,

the USB connect is used to update the fi rmware of the BeltStati on.

3- Pairing Connector

The Pairing Connector is used to pair the MasterBelt to BeltStati ons using the supplied 3.5mm

stereo mini connector.

1- Belt Clip

The Belt Clip enables the BeltStati on to be worn on the user’s belt or other clothing

item.

2- Power ON/OFF Butt on

The Power ON/OFF butt on is used to turn the BeltStati on ON or OFF. Press and

hold the Power ON/OFF butt on for two seconds to turn the BeltStati on ON. Press

for four seconds to turn the BeltStati on OFF.

3- Batt ery Compartment

The Batt ery Compartment holds either one Tempest Lithium-Polymer rechargeable

batt ery or (3) standard alkaline AA cells. To remove the batt ery door, press down on

the thumb markings and pull the batt ery door toward the bott om of the BeltStati on.

To remove batt eries from the batt ery compartment turn the BeltStati on batt ery

side down and tap the bott om of the BeltStati on on the palm of your other hand.

Please be careful to insert alkaline AA batt eries according to the marked polarity.

All of the alkaline AA cells face the same directi on. If the batt ery cover does not fi t

or close properly, the batt ery may not be inserted correctly.

4- Headset Connector

The 4-pin XLR male headset connector mates with most Dynamic or Electret headsets that have 4-pin XLR female connectors.

This Headset connector allows a user to communicate in “Dual-listen” or “Single-listen” mode on either intercom channel.

The mic detect circuit (dynamic/electret) will indicate dynamic when it sees a load of 600Ω or less. It will indicate an

electret when it sees 1kΩ or greater. Between 600Ω and 1kΩ is not recommended as it may not accurately detect mic type.

Advertising