Multiple Base Station Initialization

Multiple base stations must be “initialized” according to the following
instructions, so their frequencies will not cause interference.
After initializing each base station, register each beltpac that will be used
with that base station (See page 15).


Primary/Secondary Base Station Setting

Set the BASE switch on each base station as described below, and then
configure each base station through the initialization procedure that follows.

On the right side of each base station, set the BASE switch as follows:

1

Primary base station – Leave the BASE switch in the PRI position.

2

Secondary base stations – On each secondary base station, move the
BASE switch to the SEC position, and then press the base station
POWER switch twice to turn the power off and back on again to activate
the setting.











3

With the primary base station
powered on first, turn on the
secondary base station.

The STATUS window will show
“8” for a few seconds, and then
a double bar.