Rev. 03-23-2012

























































Quick Start Guide

SwitchLinc

TM

Relay – INSTEON

®

Remote Control On/Off Switch

(Non-Dimming), 3-Wire

Model: 2476S

-15 Amps, Rev 5.5

Introduction

Remotely control lights and other non-dimmable devices in your home at the
touch of a button. Send commands to SwitchLinc from an INSTEON
controller. Or, conveniently control other linked INSTEON devices through the
SwitchLinc paddle.

Using SwitchLinc

Tap the paddle top to turn your light on.

 Tap the paddle bottom to turn your light off.

Installation (Typical 2-Way Circuit)

Note: For multi-way circuit installation, refer to the Owner’s Manual.

1) At the circuit breaker or fuse panel, disable the circuit supplying

power to the switch.

2) Remove the wallplate from the existing switch, then unscrew the

switch and pull it out from the junction box.

3) Disconnect the wires from the switch you are replacing and ensure

you have 1/2” of bare wire on the ends.

4) To correctly identify the Line, Load, Neutral and Ground wires,

enable power to the switch from the circuit breaker or fuse panel,
use a line voltage meter, then turn the breaker off again. See Figure
1 to properly connect your wires to the INSTEON device.
Note: Mechanical switches don’t utilize Neutral wires, but they are
usually available in the back of the switch box.

5) Ensure that all wire connectors are firmly attached and that there is

no exposed copper except for the Ground wire.

6) Orient SwitchLinc with the LED bar at the left, gently place it into the

junction box and screw it into place.

7) Enable power to the switch from the circuit breaker or fuse panel.
8) Test that SwitchLinc is working properly by turning the light on and

off.

9) Reinstall the wallplate.

Using SwitchLinc as a Controller

1)

Set SwitchLinc to linking mode* by pressing and holding the Set
button until it beeps (3 seconds).

The top LED should begin blinking.

2)

At the responder, set it to the state you wish to activate from
SwitchLinc.

3)

Press and hold the responder’s Set button for 3 seconds.

SwitchLinc should double-beep and its LED should stop
blinking.

4)

Confirm that linking was successful by tapping the paddle on
SwitchLinc on and then off.

The responder should respond appropriately.

Using SwitchLinc as a Responder

1)

Set your INSTEON Controller to linking mode*. (For most
controllers, press and hold the Set button for 3 seconds or
an On/Scene button for 10 seconds.)

2)

Press and hold the Set button on SwitchLinc until it double-
beeps (3 seconds).

The top LED should flash, and then turn on solid.

3)

Confirm that linking was successful by tapping the button
you just linked to on the controller.

The load connected to SwitchLinc should respond
appropriately.

Complete Instructions, Troubleshooting and Tech Support

Owner’s Manual:

http://wiki.smarthome.com/index.php?title=2476S_Manual

Call: INSTEON Support Line at 800-762-7845

Tools Needed

Phillips and flathead screwdriver

 Wire

cutter/stripper

 Voltage tester to identify wires inside the junction box

Preparation

Installation should be performed only by a qualified electrician or a
homeowner who is familiar and comfortable with electrical circuitry. If you
have any questions regarding installation, we suggest consulting an
electrician. If you have any questions regarding setup, contact the INSTEON
Support Line.

Paddle top

(on)

LED bar

Paddle bottom

(off)

Set button

Figure 1

*Setup modes will automatically time out after 4 minutes

Limited Warranty – INSTEON warrants to original consumer of this product for a period of 2 years from date of purchase, this product will be free from
defects in material and workmanship and will perform in substantial conformity with its Owner's Manual. Warranty shall not apply to defects caused by
misuse or neglect.
Protected under U.S. and foreign patents (see www.insteon.com) © Copyright 2012
INSTEON, 16542 Millikan Ave., Irvine, CA 92606, 800-762-7845

Advertising