INSTEON SwitchLinc 2-Wire Dimmer (RF) (2474DWH) Quick Start User Manual

Quick start guide, Switchlinc™ 2-wire dimmer (rf) insteon, Remote control dimmer - model: 2474dwh

Advertising
background image

2474D Rev. 7/16/2012 12:38 PM / See Owner’s Manual for Warranty Information.

Protected under U.S. and foreign patents (see www.insteon.com)

© Copyright 2012 INSTEON, 16542 Millikan Ave., Irvine, CA 92606, 800-762-7845

Quick Start Guide

SwitchLinc™ 2-Wire Dimmer (RF)

INSTEON

®

Remote Control Dimmer - Model: 2474DWH

What’s in the Box?

SwitchLinc 2-Wire Dimmer

Three (3) wire nuts

Two (2) screws

Tools Needed

Slotted screwdriver

Phillips screwdriver

Wire cutter/stripper

Voltage meter

Installing SwitchLinc

1) At electrical panel, turn off circuit breaker(s) feeding wall box (verify that

power is off)

2) Remove wallplate, unscrew existing switch and gently pull out

3) Disconnect wires from switch

1

4) After making sure the wires are not touching, turn breaker back on

5) Use a voltage meter to identify the line, load and ground wires

6) Turn breaker back off

7) Connect wires as follows with wire nuts:

8) Mount SwitchLinc back into wall box, orienting the LED bar on left

9) Turn breaker back on

SwitchLinc LED bar and connected light/load will turn on

10) Test by tapping SwitchLinc on and off

Connected light/load will turn on and off

11) Reinstall the wallplate

Making SwitchLinc an INSTEON Responder

1) Press and hold controller button until it beeps

Controller LED will start blinking

2) Tap SwitchLinc on

Connected light/load will turn on

3) Press and hold SwitchLinc’s Set button until it double-beeps

Controller LED will stop blinking and unit will double-beep

4) Confirm link by tapping controller’s button on and off

Connected light/load will turn on and off

Owner’s Manual and Tech Support

Owner’s Manual and current Quick Start Guide:

http://www.insteon.com/support

Call: INSTEON Support Line at 800-762-7845

CAUTION: To reduce the risk of overheating and possible damage to other equipment, do not install to control a receptacle, a motor-operated appliance, a fluorescent lighting

fixture or a transformer-supplied appliance.

Gradateurs commandant une lampe a filament de tungstene – afin de reduire le risqué de surchauffe et la possibilite d’endommagement a d’autres materiels, ne pas installer

pour commader une prise, un appareil a moteur, une lampe fluorescente ou un appareil alimente par un transformateur.

1

If the wires cannot be detached by unscrewing them, cut the wires where they enter the switch, then strip ½” of insulation off the ends

SwitchLinc Wires

Wall Box Wires

Bare copper

Ground (bare copper, green wire or green screw)

Red

Load (light)

Black

Line (commonly black)