Make keypad a controller, Make keypad a responder, Owner’s manual and tech support – INSTEON Keypad Dimmer (Dual-Band) (2334-2xx US) Quick Start User Manual

Page 2: Fcc and ic warnings

Advertising
background image

2334-222/2334-232 Rev. 6/19/2013 10:25 AM / See Owner’s Manual for Warranty Information.
Protected under U.S. and foreign patents (see

www.insteon.com/patents

)

© Copyright 2013 INSTEON, 16542 Millikan Ave., Irvine, CA 92606,

866-243-8022



Make Keypad a Controller

Use Keypad button to control other INSTEON devices.
1) Tap the Keypad button of choice (for 6-button, use ON button as main scene)
2) Press and hold Keypad set button until it beeps

Keypad button LED and the set button will start blinking green

3) Turn responder on (or any other state such as on 50% or even off)
4) Press and hold responder set button until it double-beeps

Keypad will double-beep and its LED will stop blinking

5) Test by tapping Keypad button on and off

Responder load will respond appropriately
Keypad button LED will turn on and off
Keypad set button will blink green once for each successful command

Make Keypad a Responder

Control Keypad from another INSTEON device.

1)

Press and hold controller button until it beeps

Controller LED will start blinking

2)

Press and hold Keypad button to adjust load to desired brightness (or off) when

scene is activated

Connected load will respond appropriately

3)

Press and hold Keypad set button until it double-beeps

Controller will double-beep and its LED will stop blinking
Keypad will double-beep

4)

Test by tapping controller button on and off

Connected load will return to the state set in step #2

Owner’s Manual and Tech Support

Visit:

http://www.insteon.com/support

for complete manual, online tech support and latest product documents.

Call: INSTEON Support Line at 866-243-8022

FCC and IC Warnings

This device complies with FCC Rules and Industry Canada license-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause harmful
interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device.
Le present appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence. L'exploitation est autorise aux deux conditions suivantes: (1) l'appareil ne doit
pas produire de brouillage, et (2) l'utilisateur de l'appareil doit accepter tout brouillage radiolectrique subi, mme si le brouillage est susceptible d'en compromettre le fonctionnement.


CAUTION - To reduce the risk of overheating and possible damage to other equipment do not install to control a receptacle, a motor-operated appliance, a fluorescent lighting fixture, or a
transformer-supplied appliance.

Gradateurs commandant une lampe a filament de tungstene – afin de reduire le risqué de surchauffe et la possibilite d’endommagement a d’autres materiels, ne pas installer pour commader une
prise, un appareil a moteur, une lampe fluorescente ou un appareil alimente par un transformateur.

Keypad

(Responder)

Controller

Keypad

(Controller)

Responder

Advertising