Troubleshooting – INSTEON DIN Rail On/Off - 2453-222 (US), 2453-422 (EU), 2453-522 (AUS/NZ) Manual User Manual

Page 12

Advertising
background image

Page 12 of 16

2453-222/2453-422/2453-522 - Rev: 1/21/2014 7:51 AM

Weight

6.17 oz (175g)

Operating environment

Indoors

Operating temperature range

32° to 104° F (0° to 40° C)

Operating humidity range

0-90% relative humidity

Storage temperature range

-4° o to 158° F (-20° to 70° C)

Electrical

Voltage

100VAC to 240VAC

RF Frequency

US

915 MHz

EU

869 MHz

AUS/NZ

921 MHz

Electrical Frequency

50/60Hz auto detected at power-up

Load type(s)

Resistive

Inductive/capacitive

Low voltage halogen

Maximum load

US

15A – 240VAC

EU

16A – 240VAC

AUS/NZ

10A – 240VAC

3600W/240VAC Resistive

700W/240VAC Inductive/Capacitive

2000W/240VAC Bulbs/Low Voltage Halogen

Minimum load

None

User replaceable fuse

US

16A, 5x20mm slow blow/burn glass fuse

EU

No user replaceable fuse

AUS/NZ

Hardwired remote control

Yes, either latching or momentary switches supported

Retains all settings without power

Yes, saved in non-volatile EEPROM

Standby power consumption

< 1 watt

Safety approval(s)

ETL, CE, C-Tick

Certifications

FCC 15.107, 15.109, 15.249

RSS 210
EN 300 220-2, 301 489-3

AS/NZS 4268, CISPR 22

UL 1472

IEC 60669-2-1

FCC ID

SBPDR01

Troubleshooting

Problem

Possible Cause

Solution

The LED on DIN Rail is
not turning on at all and
won't control my light

DIN Rail is not getting power

Make sure the circuit breaker is turned on

Check junction box wires to ensure all connections are
tight and no bare wires are exposed

Check the light fixture to ensure all connections are tight
and no bare wires are exposed

Advertising