240V Load Controller Owner’s Manual


Page 10 of 14

X10 PROGRAMMING OPTIONS

240V Load Controller is X10 ready, meaning that it can respond to X10 commands from X10 controllers
and it can send commands to X10 devices. However, to operate 240V Load Controller in X10 mode, you
must first set up an X10 address. As it ships from the factory or after a factory reset procedure, 240V
Load Controller will not have an X10 address set up.

Setting the X10 Address

You must complete the following before 240V Load Controller will respond to X10 commands:

1)

Set 240V Load Controller to linking mode by pressing and holding the Set button until it beeps (3
seconds)

The 240V Load Controller

will

begin blinking green

You will have 4 minutes to complete the next step before linking mode automatically times out.

2)

Using an X10 controller, send the X10 address you want to assign followed by the ON command
three times

For example, to assign the address A1, you would send “A1 ON A1 ON A1 ON.”

3) Once 240V Load Controller has received the preceding sequence three times, it will exit linking mode

240V Load Controller

will

double-beep and its Status LED

will

turn on solid green if the load is on

or solid red if it is off

Removing the X10 Address

If you are no longer going to control 240V Load Controller with an X10 address, it is very important that
you unlink it, because otherwise 240V Load Controller will respond to the X10 command and may cause
the device to turn on by itself.

1) Set 240V Load Controller to linking mode by pressing and holding the Set button until it beeps (3

seconds)

The 240V Load Controller

will

begin blinking green

2) Set 240V Load Controller to unlinking mode by pressing and holding the Set button until it beeps

again (3 seconds)

The 240V Load Controller

will

begin blinking red

You will have 4 minutes to complete the next step before unlinking mode automatically times out.

3) Using an X10 controller, send the X10 address you want to remove, followed by the ON command

three times

For example, to remove the address A1, you would send “A1 ON A1 ON A1 ON.”

4) Once 240V Load Controller has received the preceding sequence three times, it will exit unlinking

mode

240V Load Controller

will

double-beep and its Status LED

will

turn on solid green if the load is on

or solid red if it is off