INSTEON Load Controller 220V / 240V 30 Amp, N/O and N/C (2477SA1, 2477SA2) Quick Start User Manual

Quick start guide, Insteon

Advertising
background image

Page 1 of 2

Rev. 07-16-2012

INSTEON Limited Warranty – INSTEON warrants to original consumer of this product for a period of 2 years from date of purchase, this product will be free

from defects in material and workmanship and will perform in substantial conformity with its Owner's Manual. Warranty shall not apply to defects caused by

misuse or neglect.

Protected under U.S. and foreign patents (see www.insteon.com) © Copyright 2012

INSTEON, 16542 Millikan Ave., Irvine, CA 92606, 800-762-7845, www.insteon.com

Installation

1) If you plan to incorporate this with INSTEON-compatible software, you can write down the INSTEON I.D. and the

location of the fixture you’ll be controlling (e.g. 01.F7.G5, water heater)

2) At the circuit breaker or fuse panel, disable the circuit supplying power to the electrical junction box that is wired to

the appliance you wish to control with 240V Load Controller

3) Remove the cover of the junction box and disconnect the two supply lines coming from the circuit breaker,

ensuring that you have ½” of bare and clean copper wire on the ends

4) See Figure 1 on the next page to properly connect 240V Load Controller to the load and the junction box. The

Ground wire will not be connected to 240V Load Controller, so cap the ground wires off with a wire nut.

5) Ensure that all connectors are firmly attached and that there is not exposed copper except for the ground wire

6) Enable power to the junction box from the circuit breaker or fuse panel

7) Test that 240V Load Controller is working properly by pressing the Set button to toggle the load on, and then off

Quick Start Guide

INSTEON

®

240V 30 Amp Load Controller (Dual-Band)

Models: 2477SA1 – Normally Open Relay

2477SA2 – Normally Closed Relay

Preparation

Because this device involves high voltage levels, it is

recommended that installation be performed only by a

qualified electrician or by a homeowner who is extremely

knowledgeable and familiar with electrical circuitry. Please

take an extra level of precaution when installing this device.

If you have any questions regarding installation, we suggest

consulting an electrician.

Tools Needed

Phillips and standard screwdrivers

Wire cutter/stripper

Various tools to mount 240V Load Controller to a wall

Introduction

Remotely control your appliances that run on voltages

between 120 and 240 Volts, up to 30 Amps (resistive loads

only).

Using 240V Load Controller

Use the Set button on 240V Load Controller to toggle the load on and off.

Status LED will be solid green when the load is on and solid red when the load is off.

See the following table for the Active LED status:

240V Load Controller Model (SKU #)

Relay Status

Active Status LED

Normally Open Relay (#2477SA1)

Open

Off

Closed

Solid green

Normally Closed Relay (#2477SA2)

Open

Off

Closed with load on

Solid green

Closed with load off

Off

Set button

Status LED

Load Active

LED