Installing your da103-107/110, Operation, Troubleshooting guide – Altinex SIDEKICKER DA103-107 User Manual

Page 8: 1 the led is not red, Distribution amplifiers

Advertising
background image

DISTRIBUTION AMPLIFIERS

400-0449-005

7

INSTALLING YOUR DA103-107/110

6

Step 1. Connect the input of the DA103-107/110

to the video output of the computer using
the cable provided.

The Signal Present

LED should be on. The LED will be red if
there is power and green if a video signal
is present.

NOTE: The

DA103-107/110

derives

power from the video output
connector of the computer. If the
computer does not supply power
at

the video connector, it is

necessary to connect the USB
connector (from the video cable
provided) to an unused USB port
on the computer. If there is no
USB port available, proceed to
Step 2 and use the external
adapter.

Step 2. Skip this step if the LED is on.

Connect the DA103-107/110’s power jack
to an AC power adapter and plug the
adapter into a working outlet.

Step 3. If the power is on, the LED on the

DA103-107/110 should be on and red;
green if a signal is present.

Step 4. Connect VGA-type cables

from the

15-pin HD output connectors on the
DA103-107/110 to the display devices.

Step 5. The DA103-107/110 is now operational.

Verify the picture quality on the receiving
monitor is equivalent to the quality as
displayed on the local monitor.

OPERATION

7

The DA103-107/110 requires no adjustments for
proper

performance.

Once

set-up, the

DA103-107/110 will work trouble-free without user
intervention.

TROUBLESHOOTING GUIDE

8

We have carefully tested and found no problems in
the supplied DA103-107/110. However, we would
like to offer suggestions for the following:

8.1 THE LED IS NOT RED.

Cause 1:

There is no power.

Solution:

Verify the DA103-107/110

is

connected to the proper power
adapter or USB port.

Solution 2: Make sure the adapter is plugged

into a working outlet and that power
is on.

Cause 2:

The cables are loose.

Solution:

Verify the power plug from the AC
adapter is plugged all the way into
the DA103-107/110.

Cause 3:

The

DA103-107/110

has a

problem.

Solution:

If there is still no power, the
DA103-107/110

may require

service. Please call ALTINEX at
(714) 990-2300.