Power restore, Factory reset, Specifications – INSTEON Open/Close Sensor (2843-222, 2421) Manual User Manual

Page 7

Advertising
background image

Page 7 of 9

2843-222/2843-422/2843-522 - Rev: 1/21/2014 7:18:39 AM

• Normally open – when door/window is closed, sensor will show open. When door/window is open, sensor will

show closed

• Normally closed – when door/window is closed, sensor will show closed. When door/window is open, sensor

will show open

Using Internal Reed Switch and External Sensors
When Open/Close Sensor external sensors input is used in conjunction with its internal reed switch, Open/Close
Sensor behaves much like several sensors connected in parallel (above), meaning:

• Open/Close Sensor will be open when both internal reed switch and external reed switch sensor terminals

show open

• Open/Close Sensor will be closed when either internal reed switch or external sensor terminals show closed

Power Restore

Open/Close Sensor stores all of its settings, such as links to other INSTEON devices, with non-volatile memory.
Because settings are saved in non-volatile memory, they will not be lost when the battery is removed.

Factory Reset

All settings and scenes will be erased and return to factory default settings.
1) If you are using Open/Close Sensor to control any responders, unlink them from Open/Close Sensor. See

Remove Open/Close Sensor as a Controller.

2) Use a small screwdriver to gently remove Open/Close Sensor main case
3) Remove battery and wait at least 15 seconds
4) Press and hold set button on Open/Close Sensor while reinstalling battery
5) Release set button when the status LED turns on

Open/Close Sensor status LED will stay on for about 4 seconds and then turn off

Specifications

General

Product name

INSTEON Open/Close Sensor (formerly #2421, TriggerLinc)

Brand/manufacturer

INSTEON

Manufacturer product number

US

2843-222 (formerly #2421)

EU

2843-422

AUS/NZ

2843-522

UPC

US

718122388912

EU

813922013009

AUS/NZ

813922013016

Warranty

2 years, limited

Operation

Status LED

Green. Blinks on activation

Operational Gap:

1/2" between magnet and main case

Sense Modes:

Jumper Installed: Open = Group 1 On, Closed = Group 1 Off

Jumper Uninstalled: Open = Group 1 On (or off), Closed = Group 2 On (or
Off)

Aux. Sensor Input:

Senses contact closure

Aux. Sensor Input Wire:

>= 20 gauge wire

Setup Memory:

Non-volatile EEPROM