7440 series, Installation instructions – KING 7440 Series Hastelloy_Monel_Stainless Steel User Manual

Page 4

Advertising
background image

(714) 891-0008 • www.kinginstrumentco.com

When it comes to flow...we’re instrumental.

4

Installation Instructions

Installation Instructions

7440 SERIES ASSEMBLY WITH INDUCTIVE

RING SENSOR

PARTS LIST:

1. Frame Assembly
2. Glass Meter Tube Assembly
3. Sensor Tension Spring
4. Inductive Ring Sensor
5. Alarm Junction Box With Cover
6. Alarm Junction Box Screw
7. Strain Connector
8. Shield

7440 Series

Hastelloy / Monel / Stainless Steel

12700 Pala Drive, Garden Grove, CA 92841

www.kinginstrumentco.com / (714) 891-0008

Meters are warranted against defects in materials and workmanship to the

original user for a period of thirteen (13) months from the date of factory

shipment, provided the meter is installed, operated and maintained in

accordance with King Instrument Company's instructions and

recommendations.

This warranty does not apply if failure is caused or contributed to by any of

the following: improper handling, improper storage, abuse, unsuitable

application of the product, lack of reasonable and necessary maintenance,

use exceeding suggested pressure and temperature maximums, improper

packaging for return, or repairs made or attempted to be made by anyone

other than King Instrument Company, Inc.

KING INSTRUMENT COMPANY, INC. MAKES NO WARRANTY

AS TO THE FITNESS OF ITS PRODUCTS FOR SPECIFIC

APPLICATIONS.

This warranty is valid for the original end-user only and does not apply to

products that have been damaged or modified. This warranty is

non-transferrable and is limited to replacement or repair. The liability of King

Instrument Company arising out of its supply of the products, or their use,

shall not in any case exceed the cost of correcting defects in the products as

set forth above.

THIS WARRANTY IS A LIMITED WARRANTY AND SHALL BE IN

LIEU OF ANY OTHER WARRANTIES, EXPRESSED OR IMPLIED,

INCLUDING BUT NOT LIMITED TO ANY IMPLIED WARRANTY

OR MERCHANTABILITY OR FITNESS FOR A PARTICULAR

PURPOSE. THERE ARE NO OTHER WARRANTIES WHICH

EXIST BEYOND THE DESCRIPTION OR FACE HEREOF.

IN NO EVENT SHALL KING INSTRUMENT COMPANY BE

LIABLE FOR LOSS OF PROFITS, INDIRECT, CONSEQUENTIAL

OR INCIDENTAL DAMAGES.

Products should be returned, prepaid, to King Instrument Company, Inc. with

proof of purchase. Call factory for Return Merchandise Authorization (RMA)

number and return instructions.

2013A

INDUCTIVE RING SENSOR:

All 7440 Series flowmeters may be fitted with one fiber optic sensor.

FIBER OPTIC SENSOR:

The fiber optic sensor is mounted to the frame with a screw in a slotted

screw for adjustability. The sensor uses a pair of fiber optic cables with an

emitter and receiver to transmit the light generated by the sensor. The

sensor can interface directly to a Programmable Logic Controller (PLC) or

when connected to a separate relay can trigger a local or remote alarm.

FIBER OPTIC SENSOR-ELECTRICAL

SPECIFICATIONS

SUPPLY VOLTAGE:

OUTPUT:

OUTPUT RATING:

10-30V DC

NPN Sinking, N.O. & N.C.

150mA max. Total Load

OUTPUT RESPONSE TIME:

1ms

HOUSING RATING:

IP67; NEMA 6

SUPPLY CURRENT:

25mA

PNP Sourcing, N.O. & N.C.

OFF STATE LEAKAGE CURRENT:

1 MICOAMP @ 30V DC

OUTPUT SATURATION VOLTAGE:

<=1V at 10mA DC

>=1.5V at 150mA DC

REPEATABILITY:

0.25ms

OPERATING TEMPERATURE:

-5°F TO +131°F

FRAME ASSEMBLY

GLASS METER TUBE ASSEMBLY

FIBER OPTIC HOUSING SCREW

FIBER OPTIC HOUSING

ALARM JUNCTION BOX SCREW

STRAIN CONNECTOR

FIBER OPTIC CABLE

FIBER OPTIC ADAPTOR

FIBER OPTIC SENSOR

SHIELD

FRAME ASSEMBLY

GLASS METER TUBE ASSEMBLY

INDUCTIVE RING SENSOR

ALARM JUNCTION BOX SCREW

STRAIN CONNECTOR

SHIELD

ALARM JUNCTION BOX WITH COVER

ALARM JUNCTION BOX WITH COVER

All 7440 Series flowmeters may be fitted with one inductive ring sensor. The

inductive ring sensor is mounted on the glass meter tube using springs to put

tension between the frame and glass meter tube. The sensor can be either

proximity or latching type and can only be used with 316SS or Carboloy floats.

The inductive ring sensor produces an electromagnetic field that senses the

metal float within the sensing zone. Inductive ring sensors are 2-wire, DC, low

current devices and are designed to be used with a remote intrinsic safety

barrier / switch isolator.

INDUCTIVE SLOT SENSOR-ELECTRICAL

SPECIFICATIONS

TYPE:

SUPPLY VOLTAGE:

OUTPUT:

OUTPUT LOAD CURRENT:

Inductive Proximity or Latching

5-25V DC (Switch Isolator)

NAMUR

<= 1mA-Float Present

>= 3mA (15mA Max.)-Float Absent

SWITCHING FREQUENCY:

2kHZ

HOUSING RATING:

IP67

WIRING:

PVC covered, 2 Conductor, 26 AWG,

6.5 Ft. Long. Brown (+) / Blue (-)

PEPPERL+FUCHS

General Purpose

Intrinsically Safe

UL:

FM:

SENSOR APPROVALS:

SWITCH ISOLATOR:

Inductive ring sensors are designed to be connected to a switch isolator for

intrinsically safe applications. The purpose of the switch isolator is to supply

electrical signals between safe and hazardous areas in either direction while

limiting the amount of energy that can be transferred even under fault

conditions. Switch isolators are available with 220VAC, 110VAC or 24VDC

supply voltage requirements, contain single pole double throw (SPDT) relays,

and are DIN rail mountable. See switch isolator specifications for electrical

connections and further details.

Intrinsically Safe

CSA:

Intrinsically Safe

CENELEC:

OPERATING TEMPERATURE:

-13°F to 104°F:

-13°F to 158°F:

1

8

" LATCHING

1

8

" PROXIMITY

1

4

" LATCHING

1

4

" PROXIMITY

SENSOR TENSION SPRING

2X

7/11/2013 1:50:17 PM

12700 Pala Drive, Garden Grove, CA 92841

www.kinginstrumentco.com / (714) 891-0008

Meters are warranted against defects in materials and workmanship to the

original user for a period of thirteen (13) months from the date of factory

shipment, provided the meter is installed, operated and maintained in

accordance with King Instrument Company's instructions and

recommendations.

This warranty does not apply if failure is caused or contributed to by any of

the following: improper handling, improper storage, abuse, unsuitable

application of the product, lack of reasonable and necessary maintenance,

use exceeding suggested pressure and temperature maximums, improper

packaging for return, or repairs made or attempted to be made by anyone

other than King Instrument Company, Inc.

KING INSTRUMENT COMPANY, INC. MAKES NO WARRANTY

AS TO THE FITNESS OF ITS PRODUCTS FOR SPECIFIC

APPLICATIONS.

This warranty is valid for the original end-user only and does not apply to

products that have been damaged or modified. This warranty is

non-transferrable and is limited to replacement or repair. The liability of King

Instrument Company arising out of its supply of the products, or their use,

shall not in any case exceed the cost of correcting defects in the products as

set forth above.

THIS WARRANTY IS A LIMITED WARRANTY AND SHALL BE IN

LIEU OF ANY OTHER WARRANTIES, EXPRESSED OR IMPLIED,

INCLUDING BUT NOT LIMITED TO ANY IMPLIED WARRANTY

OR MERCHANTABILITY OR FITNESS FOR A PARTICULAR

PURPOSE. THERE ARE NO OTHER WARRANTIES WHICH

EXIST BEYOND THE DESCRIPTION OR FACE HEREOF.

IN NO EVENT SHALL KING INSTRUMENT COMPANY BE

LIABLE FOR LOSS OF PROFITS, INDIRECT, CONSEQUENTIAL

OR INCIDENTAL DAMAGES.

Products should be returned, prepaid, to King Instrument Company, Inc. with

proof of purchase. Call factory for Return Merchandise Authorization (RMA)

number and return instructions.

2013A

INDUCTIVE RING SENSOR:

All 7440 Series flowmeters may be fitted with one fiber optic sensor.

FIBER OPTIC SENSOR:

The fiber optic sensor is mounted to the frame with a screw in a slotted

screw for adjustability. The sensor uses a pair of fiber optic cables with an

emitter and receiver to transmit the light generated by the sensor. The

sensor can interface directly to a Programmable Logic Controller (PLC) or

when connected to a separate relay can trigger a local or remote alarm.

FIBER OPTIC SENSOR-ELECTRICAL

SPECIFICATIONS

SUPPLY VOLTAGE:

OUTPUT:

OUTPUT RATING:

10-30V DC

NPN Sinking, N.O. & N.C.

150mA max. Total Load

OUTPUT RESPONSE TIME:

1ms

HOUSING RATING:

IP67; NEMA 6

SUPPLY CURRENT:

25mA

PNP Sourcing, N.O. & N.C.

OFF STATE LEAKAGE CURRENT:

1 MICOAMP @ 30V DC

OUTPUT SATURATION VOLTAGE:

<=1V at 10mA DC

>=1.5V at 150mA DC

REPEATABILITY:

0.25ms

OPERATING TEMPERATURE:

-5°F TO +131°F

FRAME ASSEMBLY

GLASS METER TUBE ASSEMBLY

FIBER OPTIC HOUSING SCREW

FIBER OPTIC HOUSING

ALARM JUNCTION BOX SCREW

STRAIN CONNECTOR

FIBER OPTIC CABLE

FIBER OPTIC ADAPTOR

FIBER OPTIC SENSOR

SHIELD

FRAME ASSEMBLY

GLASS METER TUBE ASSEMBLY

INDUCTIVE RING SENSOR

ALARM JUNCTION BOX SCREW

STRAIN CONNECTOR

SHIELD

ALARM JUNCTION BOX WITH COVER

ALARM JUNCTION BOX WITH COVER

All 7440 Series flowmeters may be fitted with one inductive ring sensor. The

inductive ring sensor is mounted on the glass meter tube using springs to put

tension between the frame and glass meter tube. The sensor can be either

proximity or latching type and can only be used with 316SS or Carboloy floats.

The inductive ring sensor produces an electromagnetic field that senses the

metal float within the sensing zone. Inductive ring sensors are 2-wire, DC, low

current devices and are designed to be used with a remote intrinsic safety

barrier / switch isolator.

INDUCTIVE SLOT SENSOR-ELECTRICAL

SPECIFICATIONS

TYPE:

SUPPLY VOLTAGE:

OUTPUT:

OUTPUT LOAD CURRENT:

Inductive Proximity or Latching

5-25V DC (Switch Isolator)

NAMUR

<= 1mA-Float Present

>= 3mA (15mA Max.)-Float Absent

SWITCHING FREQUENCY:

2kHZ

HOUSING RATING:

IP67

WIRING:

PVC covered, 2 Conductor, 26 AWG,

6.5 Ft. Long. Brown (+) / Blue (-)

PEPPERL+FUCHS

General Purpose

Intrinsically Safe

UL:

FM:

SENSOR APPROVALS:

SWITCH ISOLATOR:

Inductive ring sensors are designed to be connected to a switch isolator for

intrinsically safe applications. The purpose of the switch isolator is to supply

electrical signals between safe and hazardous areas in either direction while

limiting the amount of energy that can be transferred even under fault

conditions. Switch isolators are available with 220VAC, 110VAC or 24VDC

supply voltage requirements, contain single pole double throw (SPDT) relays,

and are DIN rail mountable. See switch isolator specifications for electrical

connections and further details.

Intrinsically Safe

CSA:

Intrinsically Safe

CENELEC:

OPERATING TEMPERATURE:

-13°F to 104°F:

-13°F to 158°F:

1

8

" LATCHING

1

8

" PROXIMITY

1

4

" LATCHING

1

4

" PROXIMITY

SENSOR TENSION SPRING

2X

7/11/2013 1:50:17 PM

7440 SERIES FIBER OPTIC SENSOR

FIBER OPTIC SENSOR:
All 7440 Series flowmeters may be fitted with one fiber optic sensor.
The fiber optic sensor is mounted to the frame with a screw in a slotted
screw for adjustability. The sensor uses a pair of fiber optic cables with
an emitter and receiver to transmit the light generated by the sensor.
The sensor can interface directly to a Programmable Logic Control-
ler (PLC) or when connected to a separate relay can trigger a local or
remote alarm.

FIBER OPTIC SENSOR-ELECTRICAL SPECIFICATIONS

SUPPLY VOLTAGE:

10-30V DC

SUPPLY CURRENT:

25mA

OUTPUT:

NPN Sinking, N.O. & N.C.

PNP Sourcing, N.O. & N.C.

OUTPUT RATING:

150mA max. Total Load

OUTPUT RESPONSE TIME:

1ms

OFF STATE LEAKAGE CURRENT: 1 MICOAMP @ 30V DC
OUTPUT SATURATION VOLTAGE: <=1V at 10mA DC

>=1.5V at 150mA DC

REPEATABILITY:

0.25ms

HOUSING RATING:

IP67; NEMA 6

OPERATING TEMPERATURE:

-5°F TO +131°F

7430 SERIES ASSEMBLY WITH

FIBER OPTIC SENSOR

PARTS LIST:

1. Frame Assembly
2. Glass Meter Tube Assembly
3. Fiber Optic Housing Screw
4. Fiber Optic Housing
5. Alarm Junction Box With Cover
6. Alarm Junction Box Screw
7. Strain Connector
8. Fiber Optic Cable
9. Fiber Optic Adaptor
10. Fiber Optic Sensor
11. Shield

Advertising