King Technology POOL FROG Mineral Hybrid System Analog User Manual

Page 14

Advertising
background image

B. Red caution light is solid or

Salt level is very high. The generator could

Drain part of the water and refill the pool.

output lights 1-7 go up

completely turn off and no longer produce

It is also recommended to periodically test

and down quickly.

chlorine until the situation is rectified.

the salt level by a professional. If above

5500 ppm, check with your dealer about drain-

ing the pool water and refilling with fresh water.

1. Make sure your filtration system is working

properly (i.e. clean filter and/or skimmer).

2. Make sure circulation time is adequate –

10. Cloudy Water

May be due to chemical imbalance

increase pump time if not.

or low water flow.

3. Make sure total alkalinity is within 60-120

ppm. Adjust with acid if needed.

4. Shock the water to eliminate build up of any

organic matter.

5. Make sure pool has a free chlorine reading

of 0.5 to 1.0 ppm.

6. Check with your dealer for more information.

Control knob set too low.

Turn control knob up (clockwise).

7. Output Level Lights
Not Responding, but
Power Light is On

Improper salt level.The system automatically

Check salt level using a test kit or your local

shuts down the output level when the salt

pool professional. See Salt Level Low or Salt

level is extremely low or extremely high.

Level High instructions above. Adjust accordingly.

Wires from control panel to cell are loose

Check the connection. Wires should be slid

or the screws to the connectors are

over the pegs on the cell and the screws

not tight.

tightened firmly. See cell-wiring diagram page 11.

8. Scale Buildup Inside Cell

Standard occurrence that needs to be

Clean cell as instructed on page 11.

cleaned approximately twice per year.

Chemical imbalance.

Balance chemicals. (Focus mostly on the
“Saturation Index” on page 16.)

9. White Flakes In Water

Normal occurrence when cell cleans itself.

Keeping the water well balanced reduces this.
(Focus mostly on the “Saturation
Index” on page 16.)

6. Salt Level High

This does no harm to the generator. Slowly

A. Red caution light is flashing.

Salt level is on the high side.

turn down the control knob to return to desired

output setting. It is also recommended to
periodically test the salt level by a professional.

Check the cell to ensure the plates are in good
condition and not coated with calcium buildup.

Dirty cell.

Cleaning the cell is recommended if it is
calcified or if the readout seems questionable.
See “Cell Cleaning” page 11.

5. Output Light #7 is
not lit when turning

Loose connection with the cell’s

Ensure the connectors are pushed completely

control knob all the

connection pegs.

over the pegs and tighten connections with a

way up.

screwdriver. See cell-wiring diagram page 11.

Add salt into the pool. See “Adding Salt” on

page 6. It is also recommended to periodically

Not enough salt due to heavy rain, splash out,

test the salt level by a professional and adjust

initial miscalculation, etc.

according to the “Salinity Demand Table” on
page 6.

Worn cell.

If none of the above resolutions worked, the
cell may be worn out and must be replaced.

14

PROBLEM

POSSIBLE CAUSES

WHAT TO DO

Advertising