1) Do: Check tightness of hose nut to be sure hose is securely attached to the tank outlet.

2) Do: Inspect hose for deterioration, cracks, softness, or brittleness. If any of these conditions are found, replace hose

before using. Replace with original manufacturer’s parts only.

3) Do: Remove pump (see Filling, Pressurizing and Spraying Instructions), inspect interior and exterior of tank for signs

of deterioration of body and bottom. Any sign of deterioration indicates possible tank weakening and could result in

explosive bursting under pressure. If any of these signs are found, discard tank immediately and replace. Do not

attempt to patch leaks, etc., as this could result in serious injury.

4) Do: Follow Filling, Pressurizing and Spraying Instructions, except use water only.

5) Do: Pump plunger 8-10 strokes and inspect for leaks.

6) Do: Direct shut-off away from you and open to make sure discharge is not clogged.

7) Do: If unit passes this test, release pressure (see Pressure Releasing Instructions), empty tank, and proceed with Filling,

Pressurizing and Spraying Instructions.

3. Pre-Use Check

4. Filling

1) Do: Turn pump handle counterclockwise and remove pump

2) Do: Prepare spray solution following all directions and safety warnings on chemical label.

3) Do: Fill tank to no more than the proper gallon marker. Do NOT: over fill to accommodate pump.

4) Do: Check pump to make sure that no grass or dirt is stuck to barrel. Replace pump in tank and tighten securely.

5. Pressurizing and Spraying

Do:

Turn handle clockwise to

tighten. Push handle down, turn

1/4 turn counterclockwise to

release.

Do:

Pump until you

feel resistance.

Do:

Push handle, down, turn 1/4 turn

clockwise to lock. Begin spraying. Re-

pump sprayer as required to maintain

spray force.

7. To Release Pressure

1) Your sprayer is equipped with a pressure relief/release valve. To release pressure lift

and hold the cap until air is completely exhausted, OR, turn the valve slowly counter-

clockwise until you hear air escaping and wait air is completely exhausted.

2) Do: Stay away from the sprayer until all air has escaped.

8. Care, Storage and Maintenance

1) Do: Rinse tank thoroughly with water only, empty, refill with water. Follow Filling, Pressurizing and Spraying

Instructions, except pump unit only 8-10 strokes.

2) Do: Open shut-off and allow water to run through discharge assembly.

3) Do: Release pressure (Follow Pressure Release Instructions), remove pump and empty sprayer.

4) Do: Store sprayer tank upside down, with pump removed, in a warm dry location.

5) Do: Periodically oil pump by dropping 10-12 drops of light oil down pump rod through opening in cover.

010538-2 (A) R0209

5A

5C

1. Hose to Tank

5B

Make sure white outlet tube

is attached to hose.

Insert tube into tank.

WARNING:

Handling the brass parts of this product will expose you to lead, a chemical known

to the State of California to cause birth defects and other reproductive harm. Wash hands after

handling.

2. Nozzle

1A

1B

Proper placement of white

outlet tube.

1C

Line up tabs on safety lock

connector with notches

on the outlet flange of

the tank. Insert tabs into

notches to form a secure

seal.

Slip hose nut down to

tank, turnclockwise

and tighten as tight as

possible by hand.

1E

Hazard: Improper use or failure to follow instructions can result in explosive failure causing

serious eye or other injury.

For safe use of this product you must read and follow all instructions.

Do not leave a pressurized sprayer in the hot sun. Heat can cause pressure build-up. Do not store or

le

ave solution in tank after use. Always wear goggles, gloves, long sleeve shirt, long pants and full foot

protection when spraying. Never use any tool to remove pump if there is pressure in sprayer. Never

stand with face or body over

top of tank when pumping or loosening pump to prevent ejecting pump

assembly and/or solution from striking and injuring you. Never pressurize sprayer by any means

other than the original pump. Do not attempt to modify or repair this product except with original

manufacturer’s parts. Never spray flammable materials or heat, pressure, or gas producing chemi-

cals. Always read and follow manufacturer’s instructions before use with this sprayer as some

chemicals may be hazardous when used with this sprayer.

Sk-1113-1

6-6136

Hose

Manguera

Tuyau

6-1898

Shut-off Handle

Mango de cierre

Poignée du robinet

6-3337

Straps

Tirantes

Sangles

For constant spraying, push down on shut-off handle and move locking

mechanism away from you. To release, squeeze handle and move the locking

mechanism back towards you.

6. Fatigue-Free Spraying

Note:

Your particular sprayer may not include all parts pictured above.

Nota:

Es posible que este pulverizador en particular no incluya todas las partes que se ilustran arriba.

Remarque :

Votre pulvérisateur particulier pourrait ne pas inclure toutes les pièces illustrées plus haut.

1D

Attach nozzle to shut-off handle or extension wand.

Parts, Piezas, Pièces

6-6141

Hose Brown

Manguera Castaño

Tuyau Brun

6-5943

Nozzle 1.0 GPM

Tobera

Buse

6-7734

Extension wand,

Vara de extensión, Rallonge

6-5797

Nozzle .5GPM

Tobera

Buse

6-7749

Extension wand,

Vara de extensión, Rallonge

6-4638

Shut-off Handle

Mango de cierre

Poignée du robinet

6-6003

Nozzle

Tobera

Buse

6-000

Nozzle

Tobera

Buse

3-7727

Extension wand,

Vara de extensión, Rallonge

Pull handle
straight up.

Insert notches from underside
of handle into plunger grooves
and turn counterclockwise.

Remove plunger and diaphragm. Clean
plunger, diaphragm and body. Flip
diaphragm and replace.

Tighten plunger clockwise until flush to top of
shut-off body. Do not over-tighten or unit may
not spray. Slide forks under plunger, push handle
down until it snaps into place.

9. Troubleshooting

-

Tank pressurizes but does not spray.

9B

9A

Handle

9C

Plunger

Body

Diaphragm

9D

Plunger flush

with body

WARNING:

Release pressure in tank before troubleshooting.

Clean shut-off (Fig. 9A- 9D)

Clean Nozzle Assembly (Fig. 9E) -Remove nozzle cap. Clean and re-assemble.

9E

Nozzle Cap

Repair Parts Kit Gaskets and Seals (not included),

Juego de piezas de reparación, empaquetaduras y juntas (no incluido)

Kit de pièces de réparation, joints et garniture d’étanchéité (non inclus) 6-5368

6A

Locking

mechanism

6B