2.2.3 M

OUNTING

C

ONFIGURATIONS

Ultra Series Cantilever Transducers can be mounted on either the inside or outside of the machine depending on the
model type purchased (refer to Figure 1 and Table D). When choosing a mounting configuration, evaluate your
options by taking the following points into consideration:

Model type

Safety

Machine Frame orientation

Ease of Assembly

TYPE "S"

MOUNTING

TYPE "PB"

MOUNTING

TYPE "FL"

MOUNTING

STATIONARY/DEAD SHAFT

SENSING ROLL

TYPE "BR"

MOUNTING

MACHINE FRAME

MACHINE FRAME

STATIONARY/DEAD SHAFT

STATIONARY/DEAD SHAFT

STATIONARY/DEAD SHAFT

SENSING ROLL

SENSING ROLL

SENSING ROLL

Figure 1 – Types of Mounting Configurations

Table D – Mounting Type and Connector Compatibility

The Connector can be located

at:

When using this type of Mounting
Configuration:

End

Side

Flange (FL)

X X

Stud (S)

X

Pillow Block (PB)

X

Bearing (BR)

X


The tension-sensing roll must not be mounted where the web wrap angle can vary, or the transducer will not
interpret the tension properly. If a variance in the wrap angle occurs, it is sensed by the transducer as a tension
change and the change is indicated on the tension indicator. In cases where it is impossible to mount the transducer
where the wrap angle does not vary, the change in indicated tension that results should be calculated and if small,
can be disregarded.

Figure 2 - Example of Varying Wrap Angles

WRAP VARIES

WRAP VARIES

PROCESS

OK FOR TENSION SENSING