No output signal, Very high output with no load, Service assistance and repair – Cleveland Motion Controls Classic Tension Transducers SC-EP REV GA User Manual

Page 10

Advertising
background image

A800-7438 Rev GA

Cleveland-Kidder Transducers; EC, ECM, SC, SCM & SC-EP

P

AGE

10

OF

10

5.5 OUTPUT SIGNAL NOT LINEAR, ZERO SHIFTS
DURING OPERATION

Check transducer and tension roll mounting. All
mounting bolts must be tight. Check that there is
no dirt or foreign matter interfering with the
transducer mounting.

5.6 NO OUTPUT SIGNAL

Check to see that all connections have been made
completely. Check for places where the
connecting cables might be crimped or cut.

5.7 VERY HIGH OUTPUT WITH NO LOAD

Check cables and connectors for good
connections and check continuity of cables with
an ohmmeter. Check for proper wiring to
transducers. Check transducer gage resistance as
given in the following chart at room temperature
with no load applied.

TRANSDUCERS GAGE RESISTANCE CHECK

Non-EP

Measurement Resistance EP

Resistance

Pin C to

240 ohms

480 ohms

Pin B

±36 ohms

±72 ohms

Pin A to

700 to

800 to

Pin B

1100 ohms

1240 ohms

Pin A to

Equal to

Equal to

Pin C

Pin A to

Pin A to

Pin B ±5 ohms Pin B ±5 ohms











6 SERVICE ASSISTANCE AND REPAIR

For additional service assistance, please obtain the
Type, MWF, and Serial Number from the
nameplate. Contact the Factory Service
Department.
Phone:

(216)

524-8800

Fax:

(216)

642-2199

Disassembly by improperly trained personnel may
result in additional damage to these units. Should
repairs be required or for warranty repairs, contact
the Customer Service Department for a return
authorization number before returning the units.