If the RJ12 cables need to be lengthened readymade / off the shelf extension
cables are freely available at your high street electrical retail outlet. If cables
are to be handmade then connections are made to pins 2 (Live) & 1 (Ground)
shown below all other pins are not used.

Troubleshooting Guide

Microphone does not move
up or down

Check that the DSP control signal is present logic +2.5

to 12 Volts is required.

Is the microphone motor cable connected?

Is the DC supply to the Controller box switched on blue

power light should be illuminating?

Check logic input cable connections between DSP

and DSP control ports on the controller box.

Microphone is picking up
noise as it is being raised /
lowered.

This is normal. The microphone must be muted by the

DSP during the raising / lowering transitions.



Specifications

Power supply requirements per control box: ARM-PSU 1

Motor activation / trigger input logic level +2.5 to +12V

Dimensions W 198 H 42 D 85mm

At the end of the life of this equipment

Dispose of according to local regulations