CNB IGC2050F User Manual

Page 9

Advertising
background image

9 / 17

XNET Network Box Camera Installation Manual

2

2

.

.

3

3

.

.

3

3

.

.

C

C

o

o

n

n

n

n

e

e

c

c

t

t

i

i

n

n

g

g

t

t

o

o

A

A

l

l

a

a

r

r

m

m

d

d

e

e

v

v

i

i

c

c

e

e

s

s

z

Alarm Input

Wires from various sensor type (IR, heat, and magnetic) can be connected to Alarm in(+)/(-) terminal as
shown in figure 2.5. (NC or NO of sensor input can be selected at Menu screen.)

Alarm Sensor device requires a separate power source.

Figure 2-5. Connecting to Alarm Input

z

Alarm Output

This terminal can only be connected up to AC 30V/400mA or DC 30V/400mA. An additional relay device
has to be used to control higher voltage or current.

Internal Circuitry External Circuitry

Figure 2-6. Connecting to Alarm Output

Advertising
This manual is related to the following products: