13.5 to 13.8 VDC/unit Average at 25 (77 )

14.4 to 15.0 VDC/unit Average at 25 (77 )

Cells per unit
Voltage per unit
Capacity

Weight
Maximum Discharge Current
Internal Resistance
Operating Temperature Range

Nominal Operating Temperature Range
Float Charging Voltage
Recommended Maximum Charging

Current Limit
Equalization and Cycle Service
Self Discharge

Terminal

Container Material

6
12
23W @ 15min-rate to 1.67V per cell @25

o

C(77

o

F)

Approx.2.1 kg(4.63 lbs)
130A(5sec)
Approx. 19

m

25

o

C±3

o

C (77

o

F±5

o

F)

2.3A

CSB Batteries can be stored for more than 6 months at
25

o

C (77

o

F). Please charge batteries before using. For

higher temperatures the time interval will be shorter.
F2-Faston Tab 250
ABS(UL 94-HB) & Flammability resistance of

(UL 94-V0) can be available upon request.

Discharge: -15 ~50 ( 5 ~122 )
Charge: -15 ~40 ( 5 ~104 )
Storage: -15 ~40 ( 5 ~104 )

Constant Power Discharge Characteristics Unit:W (25

,77 )

Constant Current Discharge Characteristics Unit:A (25

,77 )

HRL 1223W

12V 23W

Specification

Powered by

HRL 1223W is specially designed for high efficient discharge

application. Its characteristics are high energy density, small

footprint and high discharge efficiency. It can be used for more

than 260 cycles at 100% discharge in cycle service, up to 8

years in standby service.

Width (W)

Dimensions :

Unit: mm (inch)

Overall Height (H)

Container height (h)

Length (L)

106.0±1.5 (4.17

±

0.06)

101.8±1.5 (4.01±0.06)

90.0±1.0 (3.54±0.04)

70.0±1.0 (2.76±0.04)

F.V/Time

2MIN

4MIN

6MIN

8MIN

10MIN

15MIN

20MIN

30MIN

60MIN

90MIN

1.60V

50.7

32.9

25.0

20.3

17.5

12.9

10.3

7.42

4.22

3.01

1.67V

46.7

31.4

24.2

20.0

17.3

12.8

10.2

7.35

4.18

2.99

1.70V

43.8

30.6

23.8

19.7

17.0

12.6

10.1

7.29

4.17

2.98

1.75V

39.7

28.4

22.6

19.1

16.5

12.3

10.0

7.22

4.14

2.94

1.80V

35.2

26.0

21.2

17.9

15.7

11.8

9.61

7.04

4.05

2.92

1.85V

30.6

22.8

19.1

16.2

14.3

11.0

8.99

6.58

3.85

2.78

F.V/Time

2MIN

4MIN

6MIN

8MIN

10MIN

15MIN

20MIN

30MIN

60MIN

90MIN

1.60V

497

337

264

221

192

141

114

84.4

49.8

36.5

1.67V

464

326

259

219

190

140

113

84.0

49.5

36.2

1.70V

445

317

258

217

188

139

112

83.6

49.2

36.0

1.75V

410

301

247

209

182

137

111

82.8

49.0

35.9

1.80V

373

278

233

199

175

133

109

80.8

48.1

35.3

1.85V

323

252

212

183

162

124

102

76.6

46.4

34.3

CSB-manufactured

VRLA

batteries are UL-

recognized components

under UL1989.

CSB is also certified by
ISO 9001 and ISO 14001.

by TUV CERT according to ISO 9001,ISO 14001.

The system of manufacturer was certified

(http://www.csb-battery.com)

RA1308

Ratings presented herein are subject to revision without notice. Please refer to www.csb-battery.com to confirm the latest version.