CSB Battery HRL12150W User Manual

Powered by

Advertising
background image

I2-Thread lead alloy recessed terminal to accept M6 bolt

13.5 to 13.8 VDC/unit Average at 25 (77 )

14.4 to 15.0 VDC/unit Average at 25 (77 )

Cells per unit
Voltage per unit
Capacity

Weight
Maximum Discharge Current
Internal Resistance
Operating Temperature Range

Nominal Operating Temperature Range
Float Charging Voltage
Recommended Maximum Charging

Current Limit
Equalization and Cycle Service
Self Discharge

Terminal

Container Material

6
12
150W @ 15min-rate to 1.67V per cell @25

o

C(77

o

F)

Approx.11.75 kg(25.9 lbs)
225A(5sec)
Approx. 7

m

25

o

C±3

o

C (77

o

F±5

o

F)

15A

CSB Batteries can be stored for more than 6 months at
25

o

C (77

o

F). Please charge batteries before using. For

higher temperatures the time interval will be shorter.

ABS(UL 94-HB) & Flammability resistance of

(UL 94-V0) can be available upon request.

Discharge: -15 ~50 ( 5 ~122 )
Charge: -15 ~40 ( 5 ~104 )
Storage: -15 ~40 ( 5 ~104 )

Constant Power Discharge Characteristics Unit:W (25

,77 )

Constant Current Discharge Characteristics Unit:A (25

,77 )

HRL 12150W

12V 150W

Specification

Powered by

HRL 12150W is specially designed for high efficient discharge

application. Its characteristics are high energy density, small

footprint and high discharge efficiency. It can be used for more

than 260 cycles at 100% discharge in cycle service, up to 10

years in standby service.

Width (W)

Dimensions :

Unit: mm (inch)

Overall Height (H)

Container height (h)

Length (L)

172.0±2.0 (6.77±0.08)

--

195.6±2.0 (7.70±0.08)

130.0±1.5 (5.12±0.06)

F.V/Time

5MIN

7.5MIN

10MIN

15MIN

20MIN

30MIN

40MIN

50MIN

60MIN

90MIN

1.60V

169

138

116

86.7

69.6

50.4

40.0

33.5

28.9

20.8

1.67V

152

127

107

82.2

66.3

48.4

38.7

32.5

28.6

20.5

1.70V

144

122

103

80.0

64.7

47.5

38.0

32.1

28.4

20.4

1.75V

132

112

96.8

76.0

62.0

45.7

36.8

30.9

27.8

20.0

1.80V

119

104

90.0

71.1

58.4

43.8

35.1

29.8

26.8

19.5

1.85V

107

94.1

82.8

67.0

55.1

41.7

33.6

28.6

25.0

18.6

F.V/Time

5MIN

7.5MIN

10MIN

15MIN

20MIN

30MIN

40MIN

50MIN

60MIN

90MIN

1.60V

1,794

1,479

1,263

968

788

577

463

387

335

244

1.67V

1,624

1,370

1,182

935

753

559

451

386

334

239

1.70V

1,549

1,322

1,143

916

737

548

442

382

332

236

1.75V

1,422

1,234

1,075

877

704

530

428

374

325

231

1.80V

1,302

1,143

1,006

825

675

507

410

361

314

226

1.85V

1,188

1,057

943

773

639

486

396

337

296

222

CSB-manufactured

VRLA

batteries are UL-

recognized components

under UL1989.

CSB is also certified by
ISO 9001 and ISO 14001.

(http://www.csb-battery.com)

by TUV CERT according to ISO 9001,ISO 14001.

The system of manufacturer was certified

RA1308

Ratings presented herein are subject to revision without notice. Please refer to www.csb-battery.com to confirm the latest version.