Technical specifications, Connect the charger to a battery – CTEK MXS 25 User Manual

Page 4

Advertising
background image

6 • EN

TEChNiCAL SPECiFiCATiONS

Charger model

MXS 25

Model number

1055

Rated Voltage AC

220–240VAC, 50–60Hz

Charging voltage

NORMAL

14.4V,

RECOND

15.8V,

SUPPLY

13.6V

Start voltage

2.0V

Charging current

25A max

Current, mains

2.9A rms (at full charging current)

Back current drain*

<1Ah/month

Ripple**

<4%

Ambient

temperature

-20°C to +50°C, output power is reduced

automatically at high temperatures

Charger type

8-step, fully automatic charging cycle

Battery types

All types of 12V lead-acid batteries

(WET, MF, Ca/Ca, AGM and GEL)

Battery capacity

40―300Ah up to 500Ah for maintenance

Dimensions

235 x 130 x 65mm (L x W x H)

insulation class

IP44

Weight

1.9kg

*) Back current drain is the current that drains the battery if the charger is not connected

to the mains. CTEK chargers has a very low back current.

**) The quality of the charging voltage and charging current is very important. A high

current ripple heats up the battery which has an aging effect on the positive electrode.

High voltage ripple could harm other equipment that is connected to the battery. CTEK

battery chargers produce very clean voltage and current with low ripple.

SUPPLY

NORMAL

RECOND

RECOND

SUPPLY

MODE

12V/25A

MXS 25

+

+

CONNECT ThE ChARGER

TO A BATTERY

INFO

If the battery clamps are incorrectly

connected, the reverse polarity protec-

tion will ensure that the battery and

charger are not damaged.

For batteries mounted inside a

vehicle

1. Connect the red clamp to the battery's

positive pole.

2. Connect the black clamp to the vehicle

chassis remote from the fuel pipe and the

battery.

3. Connect the charger to the wall socket

4. Disconnect the charger from the wall

socket before disconnecting the battery

5. Disconnect the black clamp before the

red clamp.
Some vehicles may have positively

earthed batteries.

1. Connect the black clamp to the battery's

negative pole.

2. Connect the red clamp to the vehicle chas-

sis remote from the fuel pipe and the battery.

3. Connect the charger to the wall socket

4. Disconnect the charger from the wall

socket before disconnecting the battery

5. Disconnect the red clamp before the

black clamp.

20015541D MXS 25, Manual EU, Print file 003.indd 6

2011-10-11 11:30:15

Advertising