Analysis recond float pulse – CTEK MXS 25000 User Manual

Page 7

Advertising
background image

GB  •  7

Analysis

Recond

Float

Pulse

Tests whether the

battery retains

the energy

Reconditioning of

a drained battery

Maintenance for

maximum 

performance

Maintenance for

maximum 

battery life

Analysis

Recond

Float

Pulse

Warning indication if 

voltage drops to 1.0V in 

3 minutes.

Max 15.8V and 3A for 

4h for deeply discharged 

batteries. Otherwise 

for 30 minutes (only in

Recond mode).

13.6V with max 5A for 

max 10 days.

Pulse start at 1.9V, max 

voltage 14.4V.

13.6V max 5A.

Analysis

Recond

Float

Pulse

Warning indication if 

voltage drops to 1.0V in 

3 minutes.

13.6V with max 5A for 

max 10 days.

Pulse start at 1.9V, max 

voltage 14.4V.

Analysis

Recond

Float

Pulse

Warning indication if 

voltage drops to 4.0V in 

3 minutes.

Max 31.6V and 1.7A for 

4h for deeply discharged 

batteries. Otherwise 

for 30 minutes (only in

Recond mode).

7.V with max 14A for 

max 10 days.

Pulse start at 5.8V, max 

voltage 8.8V.

7.V max 14A.

Analysis

Recond

Float

Pulse

Warning indication if 

voltage drops to 4.0V in 

3 minutes.

7.V with max 14A for 

max 10 days.

Pulse start at 5.8V, max 

voltage 8.8V.