CTEK MXT 14000 User Manual

Page 7

Advertising
background image

GB • 7

Analysis

Recond

Float

Pulse

Tests whether the

battery retains

the energy

Reconditioning of

a drained battery

Maintenance for

maximum

performance

Maintenance for

maximum

battery life

Analysis

Recond

Float

Pulse

Warning indication if
voltage drops to 12.0V in
3 minutes.

Max 15.8V and 3A for
4h for deeply discharged
batteries. Otherwise
for 30 minutes (only in
Recond mode
).

13.6V with max 25A for
max 10 days.

Pulse start at 12.9V, max
voltage 14.4V.

13.6V max 25A.

Analysis

Recond

Float

Pulse

Warning indication if
voltage drops to 12.0V in
3 minutes.

13.6V with max 25A for
max 10 days.

Pulse start at 12.9V, max
voltage 14.4V.

Analysis

Recond

Float

Pulse

Warning indication if
voltage drops to 24.0V in
3 minutes.

Max 31.6V and 1.7A for
4h for deeply discharged
batteries. Otherwise
for 30 minutes (only in
Recond mode
).

27.2V with max 14A for
max 10 days.

Pulse start at 25.8V, max
voltage 28.8V.

27.2V max 14A.

Analysis

Recond

Float

Pulse

Warning indication if
voltage drops to 24.0V in
3 minutes.

27.2V with max 14A for
max 10 days.

Pulse start at 25.8V, max
voltage 28.8V.