Exb system extender modules – CTI Products EXB-IP Ethernet System Extender User Manual

Page 4

Advertising
background image

EXB System Extender Modules

EXB 2005-08

MCN, EXB, EXB-IM, EXB-232, EXB-IP & EXB-FI are trademarks of CTI Products, Inc.

Other trademarks referenced are properties of their respective owners.

Specifications subject to change or improvement without notice.

General Specifications

EXB-IP Ethernet Unit
S1-60962 78 Kb/s
S1-60963 1.25 Mb/s

EXB-FI Fiber Unit
S1-61112 Multimode 78K
S1-61113 Single Mode1.25M
S1-61114 Multimode 78K
S1-61115 Single Mode1.25M

EXB-IM Integral Modem Unit
S1-60602 78 Kb/s
S1-60603 1.25 Mb/s

EXB-232 Serial Unit
S1-60655 78 Kb/s
S1-60656 1.25 Mb/s

Network
Transport

UDP/IP over 10Mbps
10Base-T Ethernet

UDP/IP over 10Mbps
10Base -FL Ethernet

n/a

n/a

IP Addressing
Modes

Unicast, Unicast-Replicated,
Multicast
Static IP Address is User
programmable

Unicast, Unicast -Replicated,
Multicast
Static IP Address is User
programmable

n/a

n/a

Ethernet
Media &
Connector

10Base-T (twisted pair),
RJ-45 connector, or
15-pin D-sub female
connector (AUI)

10Base -FI Duplex
Multimode, ST (2 km max), or
Single-Mode, ST (20 km max)

n/a

n/a

Power

10 to 30 VDC (10Base-T
only)
15 to 30 VDC (AUI)
6 watts max.
Requires separate power
supply (Does not use power
from MCN network.)

15 to 30 VDC

6 watts max.
Requires separate power
supply. (Does not use power
from MCN network.)

10 to 30 VDC

5 watts max. (Counts as 2
MCN standard loads)

10 to 30 VDC

5 watts max. (Counts as 2
MCN standard loads)

Modem

n/a

n/a

Internal V.32 terbo 19.2 Kbps,
2/4 wire leased line (switch
selectable)

n/a

Telephone
Line Levels

n/a

n/a

TX: -10 or -16 dBm (switch
selectable)
RX: -45 to -16 dBm

n/a

Telco
Approvals

n/a

n/a

FCC Part 68 (U.S.)
IC CS02 & CS03 (Canada)

n/a

Serial Ports

For Configuration only

For Configuration only

n/a

2 Asynchronous Serial
DE -9M DTE (PC-AT pinout)

Baud Rates

9600 – 33.6K
Controlled by configuration
program

9600 – 33.6K
Controlled by configuration
program

n/a

9600, 19.2K, 38.4K, 57.6K,
115.2K
Switch selectable per port
8 Data, 1 Stop, No Parity
(8N1)

Size

7.5" D x 5.6" W x 1.6" H (MCN “B” size module). Add 3.5” to depth of EXB-FI, due to fiber adapter.

Mounting

Desktop with integral non-slip feet. Optional mounting brackets available (See Below)

Environmental

0-60

C at 10-95% relative humidity, non-condensing

Listings

UL1950, CSA C22.2 No.950, EN60950
Carries the CE Mark

UL1459, CSA C22.2 No.225, EN60959, Carries the CE Mark

EMI

FCC part 15

Class B

Industry Canada (IC)

Class B

EN55022

Class B

FCC part 15

Class A

Industry Canada (IC)

Class A

EN55022

Class A

EMC

Complies with EN50082 -1, IEC 801-2, 3, 4

Mounting Kits

Model

Description

S2-60472

MCN 3B Rack Mount for EIA 19" racks, 1 Rack Unit (1.75") High
Mounts (3) EXB modules.

S2-60967

MCN 2A + B Rack Mount for EIA 19" racks, 1 Rack Unit (1.75") High
Mounts (1) EXB module and (2) size A MCN modules.

Advertising
This manual is related to the following products: