CCU-2 Hardware Reference

Specifications

CTI Products, Inc.

68-11843-100

8

2.

Specifications

Size

5.5” x 4.2” x 1.5”
(140 x 107 x 38 mm)

Weight

19 oz (540 gm)

Temperature

0 – 50 ºC

Humidity

10 - 95% non-condensing

Module Power

+15 to +30 VDC

Inputs

6 sets of Force A & Force B inputs
Opto-isolated, unidirectional.
External voltage required.

Input Levels (across inputs)

Inactive:

< 0.5 VDC across inputs

Active:

5 to 30 VDC

Input Trigger Transition Polarity
(Force A or Force B)

On leading edge
(from Inactive to Active)

Fault Tolerance

A proper input transition on a Force A
or Force B input will override other
inputs, even those stuck active.

Input Impedance:

5 K Ohms, min

Number of Sections Supported

1 Section

Outputs (for control or feedback)

8 Form C Relays, magnetically latched.
All driven in parallel

Output Contacts

Bifurcated, Gold flashed
Low level (20 uA, 20 mV) to
24 VAC/VDC, 1 A Max., Resistive

Contacts used in applications which
cause contact arcing (typically
inductive, capacitive, or lamp circuits or
circuits with over 12V and 250 mA)
will not be suitable for switching low
level signals.

Maximum Power Dissipation

2 Watts

Input/Output Connection

50 pin Telco style

Network Connector

(2) RJ-45 (1 in, 1 out)

Table 1 - Module Specifications