The EXP-2000 can be utilized as an additional door and panel interface pair (Remote and Central) with an existing Suprex®
SPX-7400, SPX-7500. SPX-5600, or SPX-7200 system. Each EXP-2000 can be set to a unique address (1 through 15, see DIP
switch chart).

EXP Units used with a Cypress Suprex Gateway device will be set to the same address on both the Central and Remote sides of
the system.

SPX Systems:
The EXP-2000 is used with Suprex Gateway devices (SPX-7400/10 (FO), SPX-7500 (485), SPX-5600 (RF), SPX-7200(ET)) to
add Central and Remote pairs.

EXP-2000 Setup:

The DIP switch will be preset and labeled to determine whether the EXP-1000 will operate as a Wiegand Receiver (Remote) or
Wiegand Transmitter (Central).

Initialization of the EXP-2000:

1. Power off, Set DIP Switch #1 ON, All other DIP switches off

Set DIP Switch #3 OFF if using EXP-2000 with Suprex systems

2. Apply power to the EXP-2000.
The LED should illuminate with a solid Green indication.

3. Remove power and turn off all DIP Switches.

4. The unit is now initialized for usage with the appropriate system. Proceed to the following pages to set
DIP switches for address and Wiegand direction.

Setting EXP-2000 Addresses:

When using the EXP-2000 units with a Suprex gateway system, the Addresses must be set consecutively from 1 to the maximum
address to be used with the system. Most Suprex gateway systems will support a maximum of 8 devices
(refer to Gateway manual)

Example: An SPX-7400 system is to be setup with 4 pairs of EXP-2000 units.
The Addresses should be set: 1, 2, 3, 4 for the 4 pairs that will be used with the system and not 2,3,4,5 or 4,6,7,8 etc.

EXP-2000 Operation