AC POWER CONNECTION

To connect AC power to the controller:
1. Turn the circuit breaker for the AC gate operator power OFF

before connecting the AC input wires.
2. Turn OFF the Power Switch located on the left side of enclo-

sure before connecting the AC input wires.
3. Connect the AC input wires to the AC terminal located on the

top left of the control box. See diagram below.
4. Batteries must be installed after the AC power is on. See

Battery Power Connection.

115V 60Hz 2.5A

The E024U board is powered by a high efficiency switching power

supply that takes 115V or 230V in input and provides 36VDC to

power the board. The power supply is preset for 115V at the fac-

tory, consult with FAAC Tecnical Support for 230V wiring options.

230V

115V

The E024U board allows the connection of a 24V backup bat-

tery to provide power to operate the gate during blackouts. For

more details about how the boards handles the loss of main

power and how to configure its behaviour please see par 4.3

and DS1 switch 7.

To connect the battery use the provided cable and plug it on the

BATTERY connector on the board. Plug the other end of the

cable to the batteries, red wire to +24 and black wire to GND.

SETTING

+

DL 1 DL 2 DL 3 DL 4 DL 5

J24

SETTING

+

DL 1 DL 2 DL 3 DL 4 DL 5

J24

SETTING

+

DL 1 DL 2 DL 3 DL 4 DL 5

J24

To disable the battery charger unplug jumper J24

J24 PRESENT = BATTERY CHARGING ACTIVE
J24 NOT PRESENT = BATTERY CHARGING NOT ACTIVE