20. Free Exit Loop Vehicle Detector output (available with h3.23 and higher software): This output is active

whenever the ELD is tripped.

21. Inside Obstruction Vehicle Detector output: This relay output is activated anytime the Inside Obstruction Vehicle

Detector (IOLD) is tripped.

22. Reset/Shadow Loop Detector output: This relay output is activated anytime the Reset or Shadow loop detector

(RLD/SLD) is tripped. Since this input it not used for a sliding gate, User Relay 22 can be used in combination with a
detector to perform the function of an arming loop detector or annunciation loop detector because there is no
associated gate control logic.

23. External Latching Gate Lock Output (available in h3.25 and higher software): Activates when the Lock Interlock

Input (Term 22) is active at the start of an Open cycle and remains on until the Lock Interlock releases or 10 seconds,
whichever is sooner. Also activates at the start of a Close cycle and releases 1 second after reaching the Close limit.

24. Gate at Partial Open Position (available in h3.25 and higher software): This output is active when the partial open

position is reached or exceeded.

Clock Functions


Setting the Time and Date

The Smart Touch Controller is equipped with a 24 hour (military time), 365 day clock, so that significant events can be
logged and stamped with the time and date. This troubleshooting feature is useful to record key historical operational data
and a log of Alerts, Faults and Errors. The log can be accessed via the RS232 port. Optional software and a serial
communication cable are required in order to read this log. Contact your HySecurity distributor or HySecurity to purchase
software and download cable*.

1. To set or adjust the time, go the User menu item [CL_0] and push the Select button, so that [CL_0] blinks. Using

the Previous and/or Next buttons, change the setting from [CL_0] to 1, 2, 3 or 4 depending upon which setting is
to be changed. 1 = minutes / 2 = hours / 3 = days / 4 = months.

2. Push

the

Select button.

The display will change to a blinking (adjustable) value. Different displays will appear

(see table below) based on which [CL] value is selected:

Setting Value

Display

[CL 1]

minutes

[ni 0–59]

[CL 2]

hours

[hr 0–23]

[CL 3]

days

[dA 1-31]

[CL 4]

months

[no 1-12]

[CL 0]

Run Mode

None

3. Change the hour, minute, day or month to the desired value using the Previous and/or Next buttons, then press

the Select button to enter the change. [CL 0] will appear.


4. To change another setting, Press the Select button, (display will blink), then move to that setting using the

Previous

and /or Next buttons and repeat steps 2 and 3 until the clock is fully set.

5. When finished, be sure [CL 0] is displayed, then push MENU to exit.

6. A lithium disk battery supports the clock so that the time is not lost when the main power is off. This battery should

be replaced about every five years. Use a DL 2025 / DL 2032 or
CR 2025 / 2032 battery.




* START Configuration and Diagnostic software is available at no charge at www.hysecurity.com. Serial communication
cable and Serial to USB adaptor kits are available through HySecurity Distributors (Part Number MX000667)

.