Controlled Products Systems Group 8300SL User Manual

Page 11

Advertising
background image

9

7 - CIRCUIT BOARD LAYOUT

ENTER

STOP

CLOSE

OPEN

Figure 14 - CONTROL BOARD BUTTONS

%HFTQD "(1"4(3!. 1#+ 8.43

POWER

INPUTS

MOTOR

CONNECTION

PLUG IN

RECEIVER

COMM BUS

INPUTS

OUTPUTS

6.8 - The learning sequence

.MBDSGDKHLHSRVHSBGDR@QD@KKRDS SGDjM@KRSDOHRSN+$ 1-SGDBNMSQNK
board. To perform this task, follow the below listed steps:

1. The control board is already in the “LEARNING MODE” when shipped. In

any case follow steps of section 6.9 in order to select the most appropriate
kind of gate according to the installation. Press “OK” to allow the control
board to scan for attached items, such as sensors, photo-eye’s and other
safety devices.

2. The gate will open partially, then stop. This is being done, so that the con-

trol board can sense the type and operational condition of the drive motor.
The gate will then run to the closing limit, so that it can properly sense
where it is located.

3. The control board will then OPEN the gate slowly to establish travel and

limits.

4. Once the gate reaches the fully OPENED limit switch, the control board will

now increase gate travel speed to the highest speed allotted, and will now
travel to the fully CLOSED position at full speed.

5. The gate opener is now programmed for basic usage.

6.9 - Learning mode

If not in learning mode, follow the below listed steps;
Steps on how to place the Apollo 1050 control board into learning mode.

1. Press Function
2. Press OK
3. Select Slide
4. Select weight of gate
5. Press Enter

Unit should now be in LEARNING MODE.

Learn
Enter

“Enter” Flashes

%HFTQD +"##(2/+ 8

Advertising