Operator preparation, Gear reducer vent plug, Limit cam adjustments – Controlled Products Systems Group BGU-12-311 User Manual

Page 7

Advertising
background image

BGU

• BGU-D Barrier Gate Operator Installation Guide

- 5 -

P558 Revision X13 8-11-2011

Operator Preparation

Gear Reducer Vent Plug

In order to keep gear oil from spilling out during shipping,
gear reducers used in the BGU and BGU-D barrier gate
operators have a sealed vent plug installed at the factory.

Leaving the vent plug installed, remove the vent plug’s
breather pin to allow the gear box to vent (see Figure 5).
The breather pin can be discarded.

Limit Cam Adjustments

The limit cams for all models of barrier gate operators have
been pre-set at the factory for approximately 90 degrees of
motion. If you need to adjust this further, see Figure 6 and
follow the directions below.

1. For

more downward travel, loosen the wingnut on the LSC-1 (down)

limit cam and rotate the cam slightly in the “B” direction.

2. For

less downward travel, loosen the wingnut on the LSC-1 (down)

limit cam and rotate the cam slightly in the “A” direction.

3. For

more upward travel, loosen the wingnut on the LSO-1 (up) limit

cam and rotate the cam slightly in the “A” direction.

4. For

less upward travel, loosen the wingnut on the LSO-1 (up) limit

cam and rotate the cam slightly in the “B” direction.

NOTE: If the barrier gate operator has been custom

confi gured by the factory for reverse arm operation
(where the closed barrier arm sticks out from the service
door side of the operator) the limit switches shown in
Figure 6 will be reversed. The top limit switch will be the
open limit, the bottom limit switch will be the close limit.

GEAR REDUCER
VENT PLUG

REMOVE THE

BREATHER PIN

CLOSE LIMIT

SWITCH LSC-1

CLOSE

LIMIT CAM

OPEN LIMIT

SWITCH

LSO-1

OPEN

LIMIT CAM

DIRECTION

"B"

DIRECTION

"A"

Figure 5. Vent Plug Installation

Figure 6. Limit Cam Adjustment