Control board setup, Sync, Fail safe/secure – Controlled Products Systems Group L3NX User Manual

Page 27: Auto open” - power failure option, Last open” - power failure option, Important, Pre-warning

Advertising
background image

VIKING TECHNICAL SUPPORT 1.800.908.0884

2 5

Initial Settings

NOTE:

Installing a shunt or jumper on the pins will activate the feature.

CONTROL BOARD SETUP

“Sync”

Used only in conjunction with

the Viking Barrier gate operator model
B-12. Activating this feature allows for
synchronized operation with the B-12
operator. See page 35.

“Fail Safe/Secure”

During complete power
failure, including battery
power; determines the force
required to manually move
the gate.
• Fail Safe Mode:

By removing the wire-
jumper plug from the “Fail
Safe/Secure” connector:
The gate can move
manually with a relatively
low amount of force.

• Fail Secure Mode:

By inserting the wire-
jumper plug into the “Fail
Safe/Secure” connector:
The gate will not move
manually.

“Auto Open” - Power Failure Option

Opens the gate automatically during
power failure. Resumes normal operation
when power is restored.

“Last Open” - Power Failure Option

Will open the gate automatically when
batteries critically low.

!

IMPORTANT:

Regardless of the power failure options chosen, the gate can be moved

manually with a relatively low amount of force by following the steps for “Manual
Release” as outlined at on page 11.

“Pre-Warning”

Initiates two options for

an audio or visual warning 3 seconds
prior to gate motion and will continue:

1. Until gate reaches closed limit:

“Magnetic Lock” terminals provide a
contact between “COM” and “N.O”.

2. While gate is moving:

“Brake” terminals provide a 24v DC.

“EXT”

Available for future developments.